m+Medelevator.RU
← Поиск публикаций
Gut and liver · 2026

Optimal Sampling Site for the Diagnosis of Helicobacter pylori Infection with the Rapid Urease Test: A Prospective Cohort Study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kim Yuri, Lee Heonwoo, Kim Ga Hee, Ahn Ji Yong, Park Young Soo, Na Hee Kyong, Jung Kee Wook, Lee Jeong Hoon, Kim Do Hoon, Choi Kee Don, Song Ho June, Lee Gin Hyug, Jung Hwoon-Yong, Kim Hwa Jung

Аннотация

BACKGROUND/AIMS: The rapid urease test (RUT) is widely used as a first-line method because of its rapidity and low cost. We aimed to determine the diagnostic accuracy of the RUT versus immunohistochemical (IHC) staining of samples acquired at each gastric site in detecting Helicobacter pylori infection and identify the optimal gastric tissue acquisition site for RUT in clinical settings.

METHODS: We prospectively enrolled 377 patients who underwent esophagogastroduodenoscopy from December 2021 to June 2023. The diagnostic performance of the RUT of tissues from five gastric sites was evaluated using IHC as the reference standard. Performance was summarized by sensitivity, specificity, positive and negative predictive values, and Cohen's κ coefficient.

RESULTS: H. pylori was detected by IHC in at least one of the five biopsy sites in 61.0% of the patients. Positivity was higher at the greater curvatures (GCs) than the lesser curvatures (LCs) of both the antrum and corpus for both tests. Among single-site tests, corpus-GC biopsy yielded the best diagnostic performance (sensitivity 0.89, specificity 0.78, κ=0.65). Multisite RUTs improved agreement; the combination of antrum-GC and corpus-GC showed the highest κ (0.70) and accuracy (0.86). When stratified by the Kimura-Takemoto atrophy classification, the antrum-LC and corpus-GC pair performed best in closed-type atrophy (κ=0.80), whereas antrum-GC and corpus-GC were superior in open-type atrophy (κ=0.66).

CONCLUSIONS: The RUT demonstrated the highest diagnostic accuracy when performed at the GCs of both the antrum and corpus. A two-site biopsy approach at these locations is recommended to optimize diagnostic performance.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты