DOI 10.1007/s00534-007-1307-5

Медицинская библиотека · Journal of hepato-biliary-pancreatic surgery · 2008

Usefulness of intraoperative fluorescence imaging to evaluate local anatomy in hepatobiliary surgery.

Mitsuhashi Noboru, Kimura Fumio, Shimizu Hiroaki, Imamaki Mizuho, Yoshidome Hiroyuki, Ohtsuka Masayuki, Kato Atsushi, Yoshitomi Hideyuki, Nozawa Satoshi, Furukawa Katsunori, Takeuchi Dan, Takayashiki Tsukasa, Suda Kosuke, Igarashi Tatsuo, Miyazaki Masaru

СтатьяПеревод в очереди

Аннотация

BACKGROUND/PURPOSE: One of the major complications encountered in hepatobiliary surgery is the incidence of bile duct and blood vessel injuries. It is sometimes difficult during surgery to evaluate the local anatomy corresponding to hepatic arteries and bile ducts. We investigated the potential utility of an infrared camera system as a tool for evaluating local anatomy during hepatobiliary surgery.

METHODS

An infrared camera system was used to detect indocyanine green fluorescence in vitro. We also employed this system for the intraoperative fluorescence imaging of the arteries and biliary system in a pig. Further, we evaluated blood flow in the hepatic artery, portal vein, and liver parenchyma during a human liver transplant and we investigated local anatomy in patients undergoing cholecystectomy.

RESULTS

Fluorescence confirmed that indocyanine green was distributed in serum and bile. In the pig study, we confirmed the fluorescence of the biliary system for more than 1 h. In the liver transplant recipient, blood flow in the hepatic artery and portal vein was confirmed around the anastomosis. In most of the patients undergoing cholecystectomy, fluorescence was observed in the gallbladder, cystic and common bile ducts, and hepatic and cystic arteries.

CONCLUSIONS

Intraoperative fluorescence imaging in hepatobiliary surgery facilitates better understanding of the anatomy of arteries, the portal vein, and bile ducts.

Для цитирования: Mitsuhashi Noboru, Kimura Fumio, Shimizu Hiroaki, Imamaki Mizuho, Yoshidome Hiroyuki, Ohtsuka Masayuki, Kato Atsushi, Yoshitomi Hideyuki, Nozawa Satoshi, Furukawa Katsunori, Takeuchi Dan, Takayashiki Tsukasa, Suda Kosuke, Igarashi Tatsuo, Miyazaki Masaru. Usefulness of intraoperative fluorescence imaging to evaluate local anatomy in hepatobiliary surgery.. Journal of hepato-biliary-pancreatic surgery. 2008. DOI: 10.1007/s00534-007-1307-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.