MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejmp.2016.08.005

Медицинская библиотека · Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2016

Impact of coronal and sagittal views on lung gross tumor volume delineation.

Fitton Isabelle, Duppen Joop C, Steenbakkers Roel J H M, Lotz Heidi, Nowak Peter J C M, Rasch Coen R N, van Herk Marcel

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: To study the impact of coronal and sagittal views (CSV) on the gross tumor volume (GTV) delineation on CT and matched PET/CT scans in non-small cell lung cancer.

MATERIAL AND

METHODS

GTV delineations were performed by 11 experienced radiation oncologists on CT and PET/CT in 22 patients. Two tumor groups were defined: Group I: Primary tumors surrounded by lung or visceral pleura, without venous invasion, and without large extensions to the chest wall or the mediastinum. Group II: Tumors invading the hilar region, heart, large vessels, pericardium, and the mediastinum and/or associated with atelectasis. Tumor volumes and inter-observers variations (SD) were calculated and compared according to the use of axial view only (AW), axial/coronal/sagittal views (ACSW) and ACSW/PET (ACSWP).

RESULTS

CSV were not frequently used (57.4% out of 242 delineations on CT). For group I, ACSW didn't improve significantly mean GTVs. SDs were small on CT and on PET (SD=0.3cm). For group II, ACSW had 27-46% smaller observer variation (mean SD=0.7cm) than AW (mean SD=1.1cm). The smaller observer variation of ACSW users was associated with, on average, a 40% smaller delineated volume (p=0.038). Mean GTV of ACSWP was 21% larger than mean GTV of ACSW on CT.

CONCLUSIONS

For smaller lung tumors surrounded by healthy lung tissue the effect of multiple axis delineation is limited. However, application of coronal and sagittal windows is highly beneficial for delineation of more complex tumors, with atelectasis and/or pathological lymph nodes even if PET is used.

Для цитирования: Fitton Isabelle, Duppen Joop C, Steenbakkers Roel J H M, Lotz Heidi, Nowak Peter J C M, Rasch Coen R N, van Herk Marcel. Impact of coronal and sagittal views on lung gross tumor volume delineation.. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 2016. DOI: 10.1016/j.ejmp.2016.08.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.