MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ajo.13859

Медицинская библиотека · The Australian & New Zealand journal of obstetrics & gynaecology · 2024

Routine transabdominal cervical length screening in mid-pregnancy for the prevention of preterm birth: Is it good enough to use as a screening test?

Pedretti Michelle K, Dickinson Jan E, Doherty Dorota A, Newnham John P

Оценочное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Preterm birth (PTB) is a major pregnancy complication. There is evidence that a short cervical length in mid-pregnancy may predict women at increased risk of PTB.

AIMS: To evaluate the utility of population-based, transabdominal cervical length (TACL) measurement screening in mid-pregnancy for PTB prediction in women.

MATERIALS AND

METHODS

A transabdominal approach was initially performed, with a transvaginal (TVCL) approach offered when the TACL was <35 mm, could not be accurately measured, or the pregnancy had risk factors for PTB. TACL was compared to the directly related TVCL, when both were performed at the same assessment. Women with risk factors of PTB were included when they had both TACL and TVCL measurements performed at the same visit.

RESULTS

Data were provided for 9355 singleton pregnancies from 13 participating imaging centres. A transabdominal approach was used in 9006 (96.3%), including 682 (7.3%) TVCL combined with TACL. There were 349 (3.7%) women who had TVCL only. The median TACL was longer (40 mm) than the TVCL (38 mm). In 682 paired TACL and TVCL measurements, TACL <35 mm correctly identified 96.2% of pregnancies with TVCL <25 mm, compared with 65.4% of cases when using a TACL <30 mm. A TVCL <25 mm occurred in 59 (0.6%) women. A TACL <35 mm was associated with birth <37 weeks of gestation in 12.1% of women and birth <32 weeks of gestation in 3.9%.

CONCLUSIONS

Universal TACL is a feasible option for population screening of cervical length in a low-risk population, progressing to TVCL if the TACL is <35 mm or the cervix cannot be transabdominally accurately measured.

Для цитирования: Pedretti Michelle K, Dickinson Jan E, Doherty Dorota A, Newnham John P. Routine transabdominal cervical length screening in mid-pregnancy for the prevention of preterm birth: Is it good enough to use as a screening test?. The Australian & New Zealand journal of obstetrics & gynaecology. 2024. DOI: 10.1111/ajo.13859.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.