DOI 10.1167/iovs.67.6.30

Медицинская библиотека · Investigative ophthalmology & visual science · 2026

Development of Confocal Multispectral Imaging Using a Common Commercial Device and Application in a Healthy Aging Mouse Model.

Richard Yaashwini L, Lee Pei Ying, Bedggood Phillip, Bui Bang V, Zhao Da, Hoang Anh, Wong Vickie H Y, Metha Andrew, Finkelstein David I, Nguyen Christine T O

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To develop implementable confocal multispectral imaging (MSI) by adapting data capture and developing novel analysis on a commercially available device. Using an aging mouse model as proof-of-principle confocal MSI was compared against current reference-standard flood-illuminated hyperspectral imaging (HSI).

METHODS

Mice aged three, five, and eight months old (n = 14-19/group) underwent confocal scanning laser ophthalmoscopy retinal imaging (MultiColor module on Spectralis OCT) at three laser wavelengths returning: blue (BR, 486 nm), green (GR, 518 nm), and infrared reflectance (IR, 815 nm). Images were focused in 2D steps over a range of 20D. Average retinal reflectance was calculated for wavelengths across the dioptric range and corrected for chromatic aberration. Flood-illuminated HSI from 320 to 680 nm was also conducted.

RESULTS

MSI post-chromatic aberration correction found a significant interaction effect with age and retinal depth in IR, GR and BR (P < 0.05). The reflectance ratio of short/long wavelength shows a significant interaction effect (BR/IR, P < 0.01; average (BR,GR)/IR, P < 0.05) or trend GR/IR, P = 0.13 with advancing age and retinal depth. HSI also found a decrease in reflectance ratio with age (P < 0.0001), consistent with MSI. The effect size (Cohen's d) between HSI and MSI in the middle retina were comparable (P < 0.05).

CONCLUSIONS

Confocal MSI can be achieved on a common commercial optical coherence tomography (OCT) device with off the shelf add-on features, and after chromatic aberration correction, enables depth-resolved spectral analysis. This offers advances over flood-illuminated HSI, which does not return depth information and requires custom made or dedicated equipment. Both MSI and HSI detect similar age-related retinal reflectivity changes. This development conceptually parallels the transition from two-dimensional fundus photography to three-dimensional OCT, offering potential enhancements for selected wavelengths.

Для цитирования: Richard Yaashwini L, Lee Pei Ying, Bedggood Phillip, Bui Bang V, Zhao Da, Hoang Anh, Wong Vickie H Y, Metha Andrew, Finkelstein David I, Nguyen Christine T O. Development of Confocal Multispectral Imaging Using a Common Commercial Device and Application in a Healthy Aging Mouse Model.. Investigative ophthalmology & visual science. 2026. DOI: 10.1167/iovs.67.6.30.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.