MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-024-04642-9

Медицинская библиотека · Abdominal radiology (New York) · 2024

Differentiate adrenal lipid-poor adenoma from nodular hyperplasia with CT quantitative parameters: a feasibility study.

Bai Xin, Xu Lili, Zhang Xiaoxiao, Zheng Huimin, Zhang Hong, Zhang Yan, Zhang Jiahui, Chen Li, Peng Qianyu, Guo Erjia, Zhang Gumuyang, Lu Lin, Jin Zhengyu, Sun Hao

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To explore the potential of CT quantitative parameters in differentiating adrenal lipid-poor adenoma (LPA) from nodular hyperplasia and evaluate diagnostic performance.

MATERIALS AND

METHODS

Patients with LPA or nodular hyperplasia who underwent contrast-enhanced CT before adrenalectomy were analyzed retrospectively. The study included 128 patients (83 with LPA and 45 with nodular hyperplasia). Each lesion's unenhanced attenuation, portal-venous phase attenuation (CTp), and the portal-venous phase attenuation of the abdominal aorta were evaluated. We subsequently calculated absolute enhancement [a lesion's portal-venous phase attenuation minus unenhanced attenuation (in HUs)], relative enhancement (absolute enhancement divided by unenhanced attenuation), and the relative enhancement ratio [(absolute enhancement divided by abdominal aorta's portal-venous phase attenuation) ×100%]. Lesion number and size were recorded. Volume was assessed by ITK-snap software and the ratio of lesion volume to ipsilateral adrenal volume (volume ratio) was determined. Intergroup differences were analyzed using Student's t-test and chi-squared test. Logistic regression models were developed, and receiver operating characteristic (ROC) curves were constructed to determine the area under the ROC curve (AUC), sensitivity, and specificity. The model's performance was then compared against radiologists' subjective assessments, and the inter- and intra-reader agreement values among radiologists were calculated.

RESULTS

Portal-venous phase attenuation, volume ratio, and lesion number were independent predictors of LPA. The logistic regression model incorporating CTp, volume ratio, and lesion number achieved an AUC of 0.835, with a sensitivity of 73.5% and a specificity of 80.0%. The radiologists' diagnostic specificity and accuracy appeared to be inferior to the model. The inter-reader agreement among radiologists ranged from 0.082 to 0.535, and the intra-reader agreement of two radiologists were 0.734 and 0.583.

CONCLUSION

The portal-venous phase CT demonstrated potential in distinguishing LPA from nodular hyperplasia. The diagnostic performance of the model integrating CTp, volume ratio, and lesion number outperformed radiologists in terms of variability and reproducibility.

Для цитирования: Bai Xin, Xu Lili, Zhang Xiaoxiao, Zheng Huimin, Zhang Hong, Zhang Yan, Zhang Jiahui, Chen Li, Peng Qianyu, Guo Erjia, Zhang Gumuyang, Lu Lin, Jin Zhengyu, Sun Hao. Differentiate adrenal lipid-poor adenoma from nodular hyperplasia with CT quantitative parameters: a feasibility study.. Abdominal radiology (New York). 2024. DOI: 10.1007/s00261-024-04642-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.