Performance of the iBox Prognostication System in African American Kidney Transplant Recipients.

Truchot Agathe, Lombardi Yannis, Raynaud Marc, Aubert Olivier, Divard Gillian, Thalamas Thibaut, Astor Brad, Mandelbrot Didier, Parajuli Sandesh, Newell Kenneth A, Larsen Christian P, Karadkhele Geeta, Orandi Babak, Friedewald John J, Gupta Gaurav, Akalin Enver, Jordan Stanley C, Matas Arthur J, Molnar Miklos Z, Yamauchi Junji, Fornadi Katalin, Bentall Andrew J, Stegall Mark D, Mannon Roslyn B, Segev Dorry L, Huang Edmund, Fitzsimmons William E, Loupy Alexandre

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The iBox is a validated prognostication system that predicts long-term death-censored graft loss in kidney transplant recipients, but its performance in the specific population of African American recipients has not been fully studied.

METHODS

We conducted a multicenter study including 3,866 kidney transplant recipients from North America, of whom 1,040 (27%) were African American, to assess the impact of race on the iBox's performance in predicting graft loss. Discrimination, calibration, overall fit and clinical utility were evaluated in the whole cohort and in African American and non-African American recipients.

RESULTS

Performance metrics for the prediction of graft loss were similar in both subgroups in terms of discrimination (c-index 0.80 [95% CI: 0.77-0.83] in African American recipients and 0.83 [95% CI: 0.81-0.85] in non-African American recipients, p=0.07), and observed/expected ratios (1.08 [95% CI: 0.95-1.23] and 0.99 [95% CI: 0.88-1.10], respectively, p=0.28). No significant interaction between iBox score values and race was found in multivariable analysis stratified by transplant center (p=0.29 for the interaction term). Results were consistent between subgroups regardless of the equation used to estimate glomerular filtration rate (Kidney Recipient Specific [KRS], CKD-EPI, or MDRD), with small variations in calibration across equations.

CONCLUSIONS

The iBox prognostication system showed accurate discrimination, overall fit, and clinical utility up to 7 years post-risk evaluation in African American and non-African American kidney transplant recipients, supporting its robustness in this population.

Для цитирования: Truchot Agathe, Lombardi Yannis, Raynaud Marc, Aubert Olivier, Divard Gillian, Thalamas Thibaut, Astor Brad, Mandelbrot Didier, Parajuli Sandesh, Newell Kenneth A, Larsen Christian P, Karadkhele Geeta, Orandi Babak, Friedewald John J, Gupta Gaurav, Akalin Enver, Jordan Stanley C, Matas Arthur J, Molnar Miklos Z, Yamauchi Junji, Fornadi Katalin, Bentall Andrew J, Stegall Mark D, Mannon Roslyn B, Segev Dorry L, Huang Edmund, Fitzsimmons William E, Loupy Alexandre. Performance of the iBox Prognostication System in African American Kidney Transplant Recipients.. Journal of the American Society of Nephrology : JASN. 2026. DOI: 10.1681/asn.0000001247.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.