Background

A three-dimensional (3D) approach to absolute quantitation of 123I-metaiodobenzylguanidine (MIBG) sympathetic nerve imaging using single-photon emission tomography (SPECT) / computed tomography (CT) is not available. Therefore, we calculated absolute cardiac counts and standardized uptake values (SUVs) from images of 72 consecutive patients with cardiac and neurological diseases using 123I-MIBG SPECT/CT and compared them with conventional planar quantitation. We aimed to develop new methods for 3D heart segmentation and the quantitation of these diseases.

Methods

We manually segmented early and late SPECT/CT images of the heart in 3D, then calculated mean (SUVmean) and maximum (SUVmax) SUVs. We analyzed correlations between SUVs and planar heart-to-mediastinum ratios (HMRs), and between washout rates (WRs) derived from the SUVs and planar data. We also categorized WRs as normal or abnormal using linear regression lines determined by the relationship between SPECT/CT and planar WRs, and assessed agreement between them.

Results

We calculated SUVmean and SUVmax from all early and late 123I-MIBG SPECT/CT images. Planar HMRs correlated with early and late SUVmean (R2=0.59 and 0.73, respectively) and SUVmax (R2=0.46 and 0.60, respectively; both p<0.0001). The SPECT/CT WRs determined based on SUVmean and SUVmax (R2=0.79 and 0.45, p<0.0001) closely correlated with planar WRs. Agreement of high and low WRs between planar WRs and SPECT/CT WRs calculated using SUVmax and SUVmean reached 88.1% and 94.4% respectively.

Conclusions

We found that sympathetic nervous activity could be absolutely quantified in 3D from 123I-MIBG SPECT/CT images. Therefore, we propose a new method for quantifying sympathetic innervation on SPECT/CT images.

Для цитирования: Saito Shintaro, Nakajima Kenichi, Shibutani Takayuki, Wakabayashi Hiroshi, Yoneyama Hiroto, Konishi Takahiro, Mori Hiroshi, Takata Aki, Kinuya Seigo. Three-Dimensional Heart Segmentation and Absolute Quantitation of Cardiac 123I-metaiodobenzylguanidine Sympathetic Imaging Using SPECT/CT.. Annals of nuclear cardiology. 2023. DOI: 10.17996/anc.23-00002.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.