MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5858/2010-0098-cp.1

Медицинская библиотека · Archives of pathology & laboratory medicine · 2010

A review of sentinel laboratory performance: identification and notification of bioterrorism agents.

Wagar Elizabeth A, Mitchell Michael J, Carroll Karen C, Beavis Kathleen G, Petti Cathy Anne, Schlaberg Robert, Yasin Bushra

СтатьяПеревод в очереди

Аннотация

CONTEXT: The anthrax incident of 2001 in the United States prompted the College of American Pathologists (CAP), the Association of Public Health Laboratories, and the Centers for Disease Control and Prevention to develop exercises for Laboratory Response Network (LRN) sentinel laboratories.

OBJECTIVE

To provide an overview of the results of the CAP bioterrorism Laboratory Preparedness Survey (LPS, 2007) and Laboratory Preparedness Exercise (LPX, 2008) and assist LRN sentinel laboratories and public health agencies in planning for bioterrorism events.

DESIGN

Bioterrorism agents and nonbiothreat mimic organisms were provided in 2 mailings per year (2007 and 2008, 20 total challenges). Within each mailing, 2 to 3 agents were category A or category B bioterrorism agents (total of 10 categoric challenges). Some category A/B isolates were modified/vaccine strains. The total number of laboratories participating in these exercises ranged from 1316 to 1381. Isolate characteristics used to identify the organisms were compiled along with the participants' reporting actions. Educational commentary was provided with each exercise.

RESULTS

Acceptable identification responses were as follows: Bacillus anthracis, 90% (2007) and 99.9% (2008); Yersinia pestis, 83.8% (2007) and 87.6% (2008); and Francisella tularensis subsp Holarctica, 86.6% (2007) and 91.6% (2008). The time interval between specimen receipt and notification of results to an LRN reference laboratory decreased from more than 10 days in 2007 to 3 or 4 days in 2008 for some challenges.

CONCLUSIONS

The bioterrorism challenge program (LPS, LPX) provides important comparative data from more than 1300 sentinel laboratories that can be used by individual laboratories to evaluate their identification and LRN reporting performance.

Для цитирования: Wagar Elizabeth A, Mitchell Michael J, Carroll Karen C, Beavis Kathleen G, Petti Cathy Anne, Schlaberg Robert, Yasin Bushra. A review of sentinel laboratory performance: identification and notification of bioterrorism agents.. Archives of pathology & laboratory medicine. 2010. DOI: 10.5858/2010-0098-cp.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.