Contact lens & anterior eye : the journal of the British Contact Lens Association · 2024

Standardized clinical evaluation of dry anophthalmic socket syndrome in a real-world approach.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Francisco Zamorano-Martín, Sara Marín-Martínez, José-María Sánchez-González, Facundo Urbinati, Carlos Rocha-de-Lossada, María García-Lorente, Jessica Mata, Carmen Alba-Linero, Santiago Ortiz-Pérez, Juan Carlos Sánchez-España

Аннотация

PURPOSE: To assess which signs and eye prosthesis care habits are related to subjective discomfort in patients with dry anophthalmic socket syndrome (DASS), using standardized tools from daily practice.

METHODS: 62 anophthalmic sockets were compared with their healthy fellow eye using the Standard Patient Evaluation of Eye Dryness (SPEED) score. The correlations between SPEED questionnaire and the prosthesis care, discharge characteristics score, conjunctival inflammation score, meibomian gland dysfunction (MGD) scores and Schirmer I test were studied.

RESULT: The anophthalmic sockets group achieved a higher SPEED test score (p < 0.01), discharge score (p < 0.01), conjunctival inflammation score (p < 0.01), MGD scores (p < 0.01) and lower Schirmer I test (p < 0.01) compared with their fellow, healthy eye. Patients with a prosthesis replacement of one year or less, those with a current fit time of one year or less and those with a cleaning frequency above one month reported better SPEED, (p < 0.01), conjunctiva inflammation (p < 0.01) and MGD scores (p < 0.01).

CONCLUSION: Most anophthalmic patients suffer mild to severe DASS, which seems related to discharge, conjunctival inflammation and MGD. Moreover, certain practices related to the care of the prosthesis such as replacing with a frequency lower than yearly, current fitting time inferior to one year and a removing and cleaning regime above one month, were related to a lower discomfort sensation, conjunctival inflammation and MGD. Clinicians should consider the DASS when facing patients with anophthalmic socket and discomfort symptoms.