Preoperative mediastinal staging in early-stage lung cancer: Targeted nodal sampling is not inferior to systematic nodal sampling.

Sullivan Kerrie A, Farrokhyar Forough, Patel Yogita S, Liberman Moishe, Turner Simon R, Gonzalez Anne V, Nayak Rahul, Yasufuku Kazuhiro, Hanna Waël C

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To determine whether targeted sampling (TS), which omits biopsy of triple- normal lymph nodes (LNs) on positron emission tomography, computed tomography, and endobronchial ultrasound (EBUS), is noninferior to systematic sampling (SS) of mediastinal LNs during EBUS for staging of patients with early-stage non-small cell lung cancer (NSCLC).

METHODS

Patients who are clinical nodal (cN)0-N1 with suspected NSCLC eligible for EBUS based on positron emission tomography/computed tomography were enrolled in this prospective, multicenter trial. During EBUS, all patients underwent TS and then crossed over to SS, whereby at least 3 mediastinal LN stations (4R, 4L, 7) were routinely sampled. Gold standard of comparison was pathologic results. Based on the previous feasibility trial, a noninferiority margin of 6% was established for difference in missed nodal metastasis (MNM) incidence between TS and SS. The McNemar test on paired proportions was used to determine MNM incidence for each sampling method. Analysis was per-protocol using a level of significance of P < .05.

RESULTS

Between November 2020 and April 2022, 91 patients were enrolled at 6 high-volume Canadian tertiary care centers. A total of 256 LNs underwent TS and SS. Incidence of MNM was 0.78% in SS and 2.34% in TS, with an absolute difference of 1.56% (95% confidence interval, -0.003% to 4.1%; P = .13). This falls within the noninferiority margin. A total of 6/256 LNs from 4 patients who were not sampled by TS were found to be malignant when sampled by SS.

CONCLUSIONS

In high-volume thoracic endosonography centers, TS is not inferior to SS in nodal staging of early-stage NSCLC. This results in change of clinical management for a minority of patients.

Для цитирования: Sullivan Kerrie A, Farrokhyar Forough, Patel Yogita S, Liberman Moishe, Turner Simon R, Gonzalez Anne V, Nayak Rahul, Yasufuku Kazuhiro, Hanna Waël C. Preoperative mediastinal staging in early-stage lung cancer: Targeted nodal sampling is not inferior to systematic nodal sampling.. The Journal of thoracic and cardiovascular surgery. 2023. DOI: 10.1016/j.jtcvs.2023.11.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.