MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2013.05.037

Медицинская библиотека · European journal of radiology · 2013

Computed tomographic-guided iodine-125 interstitial implants for malignant thoracic tumors.

Huang Qiming, Chen Jin, Chen Qunlin, Lai Qingquan, Cai Siqing, Luo Kaidong, Lin Zhengyu

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the feasibility and efficacy of percutaneous interstitial brachytherapy using iodine-125 ((125)I) radioactive seeds under computed tomographic (CT) guidance for malignant thoracic tumors.

MATERIALS AND

METHODS

Forty-one patients (34 males, 7 females; 18-90 years; mean, 63.7 years) with 77 lesions (3 in the mediastinum, 7 in the chest wall, 67 in the lung) underwent percutaneous interstitial implantation of (125)I radioactive seeds under CT guidance. A treatment planning system (TPS) was employed to calculate the number and distribution of seeds preoperatively. An 18-G needle was inserted into the lesions under CT guidance and send the seeds according to TPS. Two patients with mediastinal lesions undergoing seed implantation received an artificial pneumothorax. One patient with lung carcinoma adjacent to the anterior mediastinum underwent seed implantation through the sternum. Follow-up CT was done every 2 months postoperatively.

RESULTS

The procedure was successful in all patients. No major procedure-associated death occurred. The mean duration of follow-up was 19.4 ± 1.3 months (3-49 months). A complete response (CR) was seen in 49 lesions (63.6%), partial response (PR) in 9 lesions (11.7%), stable disease (SD) in 12 lesions (12.8%), and progressive disease (PD) in 7 lesions (7.4%). The overall response rate (CR+PR) was 75.3%; the local control rate (CR+PR+SD) was 90.9%. The 1-, 2- and 3-year progression-free rates for local tumors were 91%, 88% and 88%, respectively. The 1-, 2- and 3-year survival rates were 87%, 74% and 68%, respectively.

CONCLUSION

Implantation of CT-guided (125)I seeds is feasible and effective for patients with malignant thoracic tumors.

Для цитирования: Huang Qiming, Chen Jin, Chen Qunlin, Lai Qingquan, Cai Siqing, Luo Kaidong, Lin Zhengyu. Computed tomographic-guided iodine-125 interstitial implants for malignant thoracic tumors.. European journal of radiology. 2013. DOI: 10.1016/j.ejrad.2013.05.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.