m+Medelevator.RU
← Поиск публикаций
Pacing and clinical electrophysiology : PACE · 2026

Impact of Leadless Pacemaker Implantation Position on Subclinical Right Ventricular Perforation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Young Shin, Uhm Jae-Sun, Park Je-Wook, Park Seung-Jung, Kim Ye Chan, Kim In-Soo, Lee Hye-Jeong, Kim Moon-Hyun, Park Hanjin, Kim Daehoon, Yu Hee Tae, Kim Tae-Hoon, Kim Jin-Bae, Kim Jong-Youn, Joung Boyoung, Pak Hui-Nam, Lee Moon-Hyoung

Аннотация

INTRODUCTION: Leadless pacemakers are typically implanted in the mid-septum of the right ventricle (RV) to mitigate the risk of perforation. However, reports on the precise location of these implants are limited. This study aimed to elucidate tine-based leadless pacemaker position and presence of subclinical RV perforation through computed tomography (CT) imaging, along with the associated prognosis.

METHODS: Patients who underwent heart, chest or abdomen CT after leadless pacemaker implantation were consecutively included. Two cardiologists and one radiologist reviewed the CT images to assess the position of tines and to detect RV perforation. The implantation position was categorized as the septum, RV free wall, junction of septum and RV free wall, moderator band, and RV apex. Subclinical perforation was defined as the tines of a leadless pacemaker beyond the outer myocardial contour without symptoms, pericardial effusion, hemodynamic instability, or pacemaker malfunction.

RESULTS: A total of 88 patients (age, 72.9 ± 12.1 years; 42 males) were included. The interval between procedure and CT scanning was 8.6 ± 9.2 months. In 68 patients (77.3%), the leadless pacemaker was implanted at the junction of the septum and the RV free wall. Subclinical RV perforation occurred in 15 patients (17.0%). Among patients with RV perforation, the most common implantation site was the junction of the septum and the RV free wall. None of the patients with RV perforation experienced any adverse events for 12.4 ± 12.3 months.

CONCLUSIONS: The most common leadless pacemaker implantation site is the junction of the septum and the RV free wall. Subclinical RV perforation is not uncommon and not associated with overt adverse outcomes.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты