MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jfo.2025.104773

Медицинская библиотека · Journal francais d'ophtalmologie · 2026

Iridocorneal angle changes after implantable collamer lens (ICL) implantation: A 10-year follow-up study.

Macarro-Merino A, Fernández-Vigo J I, Almorín-Fernández-Vigo I, Kudsieh B, de-Pablo-Gómez-de-Liaño L, Fernández-Vigo C, Fernández-Vigo J Á

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate changes over a 10-year period in the iridocorneal angle following implantable collamer lens (ICL) implantation.

METHODS

This retrospective study included 48 eyes of 24 patients who underwent ICL implantation. Trabecular-iris angle (TIA500), trabecular-iris space area (TISA500), and angle opening distance (AOD500) at 500μm from the scleral spur, along with vault distance, were measured using Fourier-domain anterior segment optical coherence tomography (AS-OCT). Primary endpoints were changes in TIA500, TISA500, and AOD500 from baseline to year 10. Secondary outcomes included changes in vault and predictors of anterior chamber angle opening.

RESULTS

Forty-eight eyes of 24 patients were included in the study. The mean spherical equivalent was -9.1±3.9 diopters, with 60.4% of eyes receiving a spherical ICL and 39.6% a toric ICL. Significant reductions in nasal and temporal TIA500 (P<0.001) were observed at month 1, stabilizing over 10 years. Similar patterns were found for TISA500 and AOD500. The vault demonstrated a gradual decrease over time. Multiple regression analysis revealed that preoperative TIA500 and postoperative vault at 1 month were significantly associated with TIA500 at both 1 month (P<0.0001, P=0.0050, P=0.0080, and P=0.0191, respectively) and 10 years postoperatively (P=0.0011, P=0.0016, P=0.0128, and P=0.0293, respectively) in the nasal and temporal quadrants.

CONCLUSION

ICL implantation provides long-term stability in the iridocorneal angle opening, with preoperative angle measurements serving as key predictors of long-term outcomes. This stability was maintained even after a decade, highlighting the procedure's durability in terms of anterior segment configuration.

Для цитирования: Macarro-Merino A, Fernández-Vigo J I, Almorín-Fernández-Vigo I, Kudsieh B, de-Pablo-Gómez-de-Liaño L, Fernández-Vigo C, Fernández-Vigo J Á. Iridocorneal angle changes after implantable collamer lens (ICL) implantation: A 10-year follow-up study.. Journal francais d'ophtalmologie. 2026. DOI: 10.1016/j.jfo.2025.104773.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.