MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ndt/gfl559

Медицинская библиотека · Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2006

Clinical biocompatibility of a neutral peritoneal dialysis solution with minimal glucose-degradation products--a 1-year randomized control trial.

Szeto Cheuk-Chun, Chow Kai-Ming, Lam Christopher Wai-Kei, Leung Chi-Bon, Kwan Bonnie Ching-Ha, Chung Kwok-Yi, Law Man-Ching, Li Philip Kam-Tao

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Chronic utilization of a bio-incompatible peritoneal dialysis (PD) solution with acidic pH and a high content of glucose degradation product (GDP) has been implicated as a contributing cause of peritoneal failure. We compared a newly formulated solution of neutral pH and low levels of GDP to a standard PD solution.

METHODS

Fifty new PD patients were randomized to a conventional lactate-buffered fluid (control) and a pH neutral, lactate-buffered, low GDP solution (balance). Patients were followed for 12 months. Serum samples were assayed for C-reactive protein (CRP). PD effluent was collected and assayed for cancer antigen-125 (CA125) and hyaluronan (HA). Clinical end points were the residual renal function and dialysis adequacy indices.

RESULTS

After 52 weeks of treatment, PD fluid CA125 rose from 2.45 +/- 0.96 to 14.30 +/- 2.17 U/ml (P < 0.001), and HA declined from 2.26 +/- 0.60 to 1.45 +/- 0.32 mug/ml (P = 0.07) in the balance group. The balance group had a higher PD fluid CA-125 (14.30 +/- 2.17 vs 7.36 +/- 2.23 U/ml, P = 0.007), lower HA (1.45 +/- 0.32 vs 2.55 +/- 0.32 mug/ml, P = 0.007), and lower serum CRP level (1.77 +/- 0.42 vs 7.73 +/- 2.42 mg/l, P = 0.026) than the control group at 52 weeks. There was no difference in dialysis adequacy indices, ultrafiltration volume, urine output, residual renal function, peritonitis rate or need of hospitalization in 1 year.

CONCLUSION

As compared to conventional PD solution, the use of balance, a neutral pH, low GDP solution resulted in a superior profile of PDE mesothelial cell marker and a lower degree of systemic inflammation, and the difference was maintained for 1 year. It remains to be determined whether these effects could result in better long-term clinical outcome.

Для цитирования: Szeto Cheuk-Chun, Chow Kai-Ming, Lam Christopher Wai-Kei, Leung Chi-Bon, Kwan Bonnie Ching-Ha, Chung Kwok-Yi, Law Man-Ching, Li Philip Kam-Tao. Clinical biocompatibility of a neutral peritoneal dialysis solution with minimal glucose-degradation products--a 1-year randomized control trial.. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 2006. DOI: 10.1093/ndt/gfl559.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.