MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10620-026-09970-y

Медицинская библиотека · Digestive diseases and sciences · 2026

Endoscopic Ultrasound-Guided Franseen Fine-Needle Biopsy for Solid Pancreatic Lesions: A Systematic Review and Meta-Analysis.

Bhat Adnan, Arham Muhammad, Ali Zahra, Ishtiaq Saniya, Abdul Rehman Muhammad, Ahmed Adil, Chauhan Anchit, Tareen Haseeb Khan, Bakht Kinza, Haider Faseeh, Dad Allah, Creech Lindsey, Novikov Aleksey, Draganov Peter V

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

INTRODUCTION

Accurate tissue acquisition (TA) of solid pancreatic lesions is essential for guiding treatment with endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) being the preferred method. Among FNB designs, the three-pronged Franseen-tip needle demonstrates strong diagnostic performance, though direct head-to-head comparisons with other FNB designs remain limited.

METHODOLOGY: This meta-analysis was conducted in accordance with PRISMA guidelines (PROSPERO: CRD420251123856). Eligible studies enrolled patients with solid pancreatic lesions who underwent EUS-guided FNB, directly compared the Franseen-tip with other FNB needles. Six databases were systematically searched through July 2025, and study selection, data extraction, and risk of bias assessment (QUADAS-2 tool) were performed independently by two reviewers. Pooled estimates were generated using random-effects and bivariate hierarchical models.

RESULTS

Sixteen studies (2,010 Franseen vs. 2,811 comparator) were included. Bivariate analysis showed that sensitivity and specificity of the Franseen needle were comparable to newer-generation comparator needles (sensitivity 91.3% vs. 94.0%; specificity 99.99% vs. 99.15%), whereas older-generation needles demonstrated lower sensitivity (80.8%) and inferior discriminatory performance (Negative Likelihood Ratio [LR⁻] 0.19 vs. 0.09). Diagnostic accuracy was higher with the Franseen needle (RR 1.07, 95% CI 1.01-1.14; I2 = 69%). Sample adequacy was similar overall (RR 1.04, 95% CI 0.95-1.14) but superior to older-generation needles (RR 1.19, 95% CI 1.02-1.41) and in lesions > 30 mm (RR 1.14, 95% CI 1.02-1.28, I2 = 81.2%). The Franseen needle achieved nominally strong diagnostic performance (DOR 116.6), although small-study effects were observed. Primary procedural outcomes were comparable between Franseen and comparator needles, including technical success (RR 1.00, 95% CI 0.98-1.02) and histological core procurement (RR 1.04, 95% CI 0.92-1.17). The Franseen needle had fewer low-cellularity samples (RR 0.56, 95% CI 0.45-0.69) and lower specimen bloodiness (RR 0.48, 95% CI 0.25-0.90) but a slightly higher overall adverse event rate (RR 1.29, 95% CI 1.06-1.57).

CONCLUSION

The Franseen needle provides superior diagnostic accuracy and sample adequacy compared to older-generation FNB needles with comparable performance to newer-generation designs. It reduces low-cellularity samples and specimen bloodiness, although adverse events are slightly increased, with other primary procedural outcomes remaining comparable.

TRIAL REGISTRATION: PROSPERO (Registration No. CRD420251123856).

Для цитирования: Bhat Adnan, Arham Muhammad, Ali Zahra, Ishtiaq Saniya, Abdul Rehman Muhammad, Ahmed Adil, Chauhan Anchit, Tareen Haseeb Khan, Bakht Kinza, Haider Faseeh, Dad Allah, Creech Lindsey, Novikov Aleksey, Draganov Peter V. Endoscopic Ultrasound-Guided Franseen Fine-Needle Biopsy for Solid Pancreatic Lesions: A Systematic Review and Meta-Analysis.. Digestive diseases and sciences. 2026. DOI: 10.1007/s10620-026-09970-y.