INTRODUCTION

A better 3D visualisation of the lymphatic system could provide more accurate cancer treatment approaches, but this requires contrast agent injections. Since lymphatic vessels are very small, cannulations to administer contrast agent are very difficult to perform manually. As such, a dedicated set up for lymphatic vessel micro cannulations is required.

MATERIALS AND

METHODS

A micromanipulator rig for full body micro cannulations was constructed. The rig consists of an aluminium frame that can be positioned over a dissection table. It combines the micromanipulator with a sliding gantry plate and a double jointed positioning system to provide as many possible angles of approach as possible. Fluid pressure control devices and a surgical microscope can also be included in the set up.

RESULTS

Micro cannulations on a full body could successfully be performed using the micromanipulator rig. After only a short learning curve to explore the movement possibilities/range of the device, the micromanipulator rig quickly outperformed manual micro cannulations.

CONCLUSIONS

Given the short learning curve and the success rate of the micro cannulations with the micromanipulator rig, we would strongly recommend other microvascular researchers to use the micromanipulator rig for future experiments involving micro cannulations.

Для цитирования: Stouthandel Michael E J, Forouhar Danial, Debbaut Charlotte, Deviche Jurgen, De Graeve Liesl, Depypere Bernard, Meire Maarten, Adriaens Dominique, Van Hoof Tom. Construction of an experimental set up to perform full body micro cannulations of sub-millimetric vessels in an anatomical research setting.. PloS one. 2026. DOI: 10.1371/journal.pone.0358264.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.