A novel treatment for bile duct injury with a tissue-engineered bioabsorbable polymer patch.

Aikawa Masayasu, Miyazawa Mitsuo, Okamoto Kojyun, Toshimitsu Yasuko, Torii Takahiro, Okada Katsuya, Akimoto Naoe, Ohtani Yoshihide, Koyama Isamu, Yoshito Ikada

СтатьяПеревод в очереди

Аннотация

BACKGROUND

With the recent widespread use of laparoscopic cholecystectomy and living-donor liver transplantation, complications involving the biliary system, and stenosis in particular, are encountered frequently. Although various invasive and noninvasive techniques are now available for the treatment of biliary stenosis, recurrence and other problems limit their value and utility. Our group sought to investigate whether a bioabsorbable polymer (BAP) patch could serve as a novel treatment for biliary stenosis.

METHODS

In anesthetized hybrid pigs (n = 12), a spindle-shaped portion of the lower common bile duct wall was excised, and a BAP patch was implanted at the excision site. The animals underwent repeat laparotomy at 5 weeks (n = 6) and at 4 months (n = 6) after implantation to recover the graft sites for gross and histologic studies. Blood chemistry was analyzed from samples taken during the patch implantation and recovery.

RESULTS

All of the recipient pigs survived until killing. All gained weight and showed no evidence of jaundice. The BAP-patched duct remained patent without obstruction at 5 weeks postimplantation. Blood chemistry did not reveal any increases in hepatobiliary enzyme activities. Histology showed accessory glandular structures in the neo-bile duct. At 4 months, the graft site was indistinguishable from the native duct. Intra-operative cholangiography revealed dilation of the patched site, but no dilatation of the intrahepatic bile ducts. Blood chemistry values were within normal ranges. Histology at the site of the patch confirmed the growth of a cuboidal columnar epithelium similar to that of the native duct.

CONCLUSION

The bile duct was dilated only focally at the site of implantation. This newly designed substitute has potential for application as a novel treatment for biliary injury and stenosis.

Для цитирования: Aikawa Masayasu, Miyazawa Mitsuo, Okamoto Kojyun, Toshimitsu Yasuko, Torii Takahiro, Okada Katsuya, Akimoto Naoe, Ohtani Yoshihide, Koyama Isamu, Yoshito Ikada. A novel treatment for bile duct injury with a tissue-engineered bioabsorbable polymer patch.. Surgery. 2009. DOI: 10.1016/j.surg.2009.10.049.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.