AIM: To evaluate the efficiency of last image capture in interpreting a hysterosalpingogram (HSG) when compared to conventional spot views; to confirm its validity in showing pathology; to establish its use as the preferred method; and to decrease the radiation dose to the patient.

MATERIALS AND

METHODS

The study population consisted of women aged ≥18 years. A standard technique was performed including additional five last image capture after each spot view. Every patient had two stacks of images, one with the exposure film and one with the last image capture. The images were interpreted separately (high-dose versus low-dose) and blindly by two radiologists with different levels of training assessing for uterine abnormalities, fallopian tube abnormalities, peritoneal spillage, and incidental findings. Inter-reading variability was calculated using Kohen's kappa.

RESULTS

Discrepancies between exposure film and last image capture were detected in only a minority of cases for all variables. Except for the presence of strictures, there was at least substantial agreement between the readers and almost perfect agreement regarding peritoneal spillage and fallopian tube patency, both on exposure film and last image capture.

CONCLUSION

Reduction in radiation dose without compromising the diagnostic efficacy of HSG is mandatory. If the study is of sufficient quality and deemed negative on last image capture, conventional spot view can be avoided. If further detail is required, standard spot views can still be obtained. Using last image capture instead of spot films has the potential to reduce the overall radiation dose by up to 78%.

Для цитирования: Chahine R, Zadeh C, Zeid F Abou, Al-Kutoubi A. Hysterosalpingography: a step up for dose reduction.. Clinical radiology. 2023. DOI: 10.1016/j.crad.2023.10.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.