MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2015.08.015

Медицинская библиотека · The Journal of arthroplasty · 2015

The Inadequacy of Short Knee Radiographs in Evaluating Coronal Alignment After Total Knee Arthroplasty.

Park Andrew, Stambough Jeffrey B, Nunley Ryan M, Barrack Robert L, Nam Denis

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Prior studies have associated coronal alignment after total knee arthroplasty (TKA) with implant survivorship. Results have been based on either the femorotibial angle (FTA) on a short knee film or the hip-knee-ankle angle (HKA) on a full-length radiograph. The purpose of this study was to determine if the FTA on short knee radiographs can accurately predict the true HKA alignment after TKA.

METHODS

Two orthopedic surgeons measured the FTA, HKA, medial proximal tibial angle, and lateral distal femoral angle in 262 patients who had both short and full-length standing radiographs before and/or after primary TKA. Overall coronal alignment was considered neutral if the FTA was between 2.4° and 7.2° on short knee x-rays or if the HKA was between -3° and 3° on full-length films.

RESULTS

Preoperatively, 13.9% (26/187) of knees had a neutral FTA on short films, but 50% (13/26) of those were in varus or valgus on full-length films. Postoperatively, 51.4% (106/206) of knees had a neutral FTA on short films, but 27.4% (29/106) of those knees were in varus or valgus on full-length films. When comparing alignment classifications (neutral, varus, or valgus) based on the short vs full-length images, 13.9% (26/187) of patients had discordant classifications on preoperative imaging, and 33.0% (68/206) had discordant classifications on postoperative imaging.

CONCLUSION

A significant proportion of patients were misclassified as varus, valgus, or neutral based on the FTA when compared to the HKA. Short knee x-rays serve as an inaccurate proxy for full-length films when assessing coronal alignment after TKA.

Для цитирования: Park Andrew, Stambough Jeffrey B, Nunley Ryan M, Barrack Robert L, Nam Denis. The Inadequacy of Short Knee Radiographs in Evaluating Coronal Alignment After Total Knee Arthroplasty.. The Journal of arthroplasty. 2015. DOI: 10.1016/j.arth.2015.08.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.