Rapid head and neck tissue identification in thyroid and parathyroid surgery using optical coherence tomography.

Yang Nathan, Boudoux Caroline, De Montigny Etienne, Maniakas Anastasios, Gologan Olga, Madore Wendy-Julie, Khullar Sharmila, Guertin Louis, Christopoulos Apostolos, Bissada Eric, Ayad Tareck

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Optical coherence tomography (OCT) is a noninvasive imaging modality that may reproduce the microarchitecture of tissues in real-time. This study examines whether OCT can render distinct images of thyroid, parathyroid glands, adipose tissue, and lymph nodes in both healthy and pathological states.

METHODS

Twenty-seven patients undergoing thyroidectomy, parathyroidectomy, and/or neck dissection for thyroid cancer were recruited prospectively for imaging prior to histopathological analysis.

RESULTS

Based on 122 imaged specimens, qualitative OCT descriptions were derived for healthy thyroid, parathyroid gland, adipose tissue, and lymph node. The frequencies at which distinguishing features were present for each tissue type were 88%, 83%, 100%, and 82%. OCT appearance of pathological specimens were also described.

CONCLUSIONS

Healthy neck tissues have distinct OCT appearances, which could facilitate parathyroid identification during thyroidectomies. However, images of parathyroid adenomas could be confused with those of lymph nodes, and benign and malignant thyroid nodules could not be differentiated.

Для цитирования: Yang Nathan, Boudoux Caroline, De Montigny Etienne, Maniakas Anastasios, Gologan Olga, Madore Wendy-Julie, Khullar Sharmila, Guertin Louis, Christopoulos Apostolos, Bissada Eric, Ayad Tareck. Rapid head and neck tissue identification in thyroid and parathyroid surgery using optical coherence tomography.. Head & neck. 2019. DOI: 10.1002/hed.25972.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.