m+Medelevator.RU
← Поиск публикаций
Physics in medicine and biology · 2026

Reconstructing delivered dose in real time: a beam physics-embedded, language-model-driven approach.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wang Yuli, Wang Jing, Zhang Jiahan, Sun Yuhang, Chao Ming, Xia Junyi, Liu Ruirui, Wang Shuo, Lei Yu, Goodman Karyn A, Liu Tian, Lei Yang

Аннотация

Objective.To develop a fast and accurate physics-informed framework for real-time three-dimensional dose reconstruction directly from machine delivery beams for adaptive radiotherapy and intra-fraction dose monitoring.Approach.We propose a two-stage beam physics-driven dose reconstruction framework that integrates machine photon beam characteristics into fluence-to-dose estimation. In Stage 1, beam-related physical characteristics, including beam profiles and percent depth dose, are extracted from the institutional beam database using a large language model (LLM) assistant tuned on beam commissioning guidelines and encoded as beam-specific priors. In Stage 2, beam-wise fluence-to-dose reconstruction is performed in beam-eye-view space using a multimodal neural network that incorporates BEV-aligned CT images, optimal fluence, and the LLM-derived beam priors. Training uses a composite physics-aware loss, and performance is evaluated using two-dimensional and three-dimensional gamma analysis.Main Results.The study included 180 lung radiotherapy patients for model development and internal evaluation, and an external prostate cohort of 5 patients for cross-site testing. The predicted dose distributions showed strong agreement with reference dose maps, with residual errors mainly confined to low-dose regions and within Gy relative to a maximum dose of approximately 75 Gy. The proposed framework achieved a mean 3D gamma passing rate (3%, 2 mm/10%) of, outperforming 3D U-Net (), Dose-Net (), and CLIP-UNet () (). The corresponding mean 2D gamma passing rate was. External testing achieved a gamma passing rate of. The model required approximately 6.3 seconds to reconstruct a 9-field treatment plan.Significance.By incorporating LLM-encoded beam physics into a multimodal dose reconstruction framework, this method improves dosimetric accuracy over existing learning-based approaches while maintaining rapid inference, supporting its potential for adaptive radiotherapy and real-time three-dimensionalin vivodosimetry.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты