MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/asj/sjag191

Медицинская библиотека · Aesthetic surgery journal · 2026

Prepectoral Direct-to-implant Breast Reconstruction Without ADM or Mesh: A Prospective Single-surgeon Series of 210 Patients and 349 Breasts.

Celet Ozden Burcu, Sevindik Gamze Aytas, Yildirim Nilufer, Yilmaz Cem, Karanlik Hasan, Gun Koplay Tugba, Igci Abdullah

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Prepectoral breast reconstruction reduces postoperative morbidity and eliminates animation deformity. Although acellular dermal matrices (ADM) and mesh have traditionally been used to stabilize prepectoral implants, emerging evidence has questioned their value and highlighted their association with postoperative complications.

OBJECTIVES

This study presents a single-surgeon experience using 4-micron surface implants without ADM or mesh in immediate prepectoral direct-to-implant reconstruction.

METHODS

This is a prospective single-center, single-surgeon study involving patients who underwent immediate prepectoral, breast reconstruction using Motiva Ergonomix2 implants, between September 2023 and March 2025. Early and mid-term complications, aesthetic outcomes, and patient-reported satisfaction (BREAST-Q) were analyzed.

RESULTS

A total of 210 consecutive patients (349 breasts) underwent this surgical procedure with a median follow-up of 12 months (range: 3 to 21 months). Early complications occurred in 26.1% of breasts, most commonly incision dehiscence (5.2%), hematoma (3.7%), and partial nipple-areola-complex (NAC) necrosis (2.9%). Capsular contracture (Grade III/IV) occurred in 7.7% and implant rippling in 6%. Twenty-eight breasts (8%) required unplanned reoperation. Total implant loss occurred in 1.1% of breasts. Cosmetic outcomes (n=143) were rated "excellent" or "good" in >75% of cases, approaching 92% in bilateral prophylactic mastectomies. BREAST-Q responses (n=129) demonstrated a postoperative breast satisfaction score of 64.96%, and implant satisfaction of 6.6/8.

CONCLUSIONS

This technique demonstrates low complication and implant loss rates, satisfactory aesthetic results, and high patient-reported satisfaction. These findings support Ergonomix2 implants as a safe, biocompatible, and potentially cost-effective option for prepectoral reconstruction.

Для цитирования: Celet Ozden Burcu, Sevindik Gamze Aytas, Yildirim Nilufer, Yilmaz Cem, Karanlik Hasan, Gun Koplay Tugba, Igci Abdullah. Prepectoral Direct-to-implant Breast Reconstruction Without ADM or Mesh: A Prospective Single-surgeon Series of 210 Patients and 349 Breasts.. Aesthetic surgery journal. 2026. DOI: 10.1093/asj/sjag191.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.