Dual Tracer 99mTc-Pertechnetate/99mTc-MIBI Dual-Time-Point SPECT/CT Parathyroid Gland Assessment Regarding to Parathyroid Gland Size and Biochemical Parameters - Two Years Single Imaging Centre Experience.
Аннотация
INTRODUCTION
Preoperative parathyroid imaging is inevitable part of focused parathyroid surgery. The aim of our study was assessment of parathyroid scintigraphy diagnostic accuracy regarding to size and metabolic parameters of hyperfunctioning parathyroid tissue.
MATERIAL AND
METHODS
Parathyroid scintigraphy for suspected primary hyperparathyroidism was performed in 95 patients during years 2015 and 2016. Of them, 75 patients with known clinical outcome (40 underwent surgery, 35 had documented laboratory follow-up) were further retrospectively evaluated. The performance of dual tracer 99mTc-pertechnetate and 99mTc-MIBI subtraction and dual-time-point 99mTc-MIBI imaging with SPECT/CT was analysed. Serum parathyroid hormone (PTH), calcaemia, ionized calcaemia and phosphataemia and ultrasound detected adenoma volume and largest diameter in false negative and true positive findings were compared using Mann-Whitney test.
RESULTS
Sensitivity and specificity of parathyroid scintigraphy was 74.5% and 95.8%, respectively. NPV was 63.8% and PPV 97.4%. Hyperfunctioning parathyroid tissue detectability was almost significantly associated with hypophosphataemia and PTH levels.
CONCLUSION
Parathyroid scintigraphy provides high sensitivity and superior specificity in parathyroid adenoma location, nevertheless the diagnostic accuracy tends to decline in smaller adenomas and in less metabolically active parathyroid tissue causing only subtle biochemical changes. 18F-Fluorocholine PET/CT or 3D SPECT/CT subtraction should be a reasonable option for those cases.