MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1361-6560/ae944e

Медицинская библиотека · Physics in medicine and biology · 2026

Pulse-resolved tumor control probability modeling for FLASH radiotherapy using a variable-time treatment-course framework.

Lee Tae Kyu

СтатьяПеревод в очереди

Аннотация

Objective.FLASH radiotherapy introduces beam temporal structure at the pulse and sub-pulse scale, whereas most tumor control probability (TCP) models are formulated at the fraction or treatment-course scale. This study developed, a pulse-resolved extension of the published Lee-Rosen time-dependent TCP formulation, here denoted, to connect FLASH beam microstructure, oxygen/radical kinetics, biological repair, and treatment-course repopulation.Approach.TCPLRwas used as the parent treatment-course TCP model because it accommodates variable interfraction timing and kick-off-time-dependent accelerated repopulation. Its conventional cumulative survival term was replaced by a FLASH-aware survival term derived from a reduced-order oxygen/radical ordinary differential equation kernel. Each FLASH fraction was represented as a pulse train. The same oxygen/radical kinetics, lesion-yield calculation, and post-fraction repair layer were also implemented for standard-dose-rate continuous delivery to provide an internal comparator. The implementation was verified against uniform-dose benchmarks reported in the original Lee-Rosen publication describingand then evaluated using exploratory FLASH, repair, pulse-structure, and standard-dose-rate scenarios.Main results.Conventional verification reproduced published benchmark trends, with maximum absolute differences of 1.44, 1.21, and 3.48 percentage points for head-and-neck, breast, and prostate cases, respectively. In a 3 × 8 Gy starter case, calibrated null-FLASH TCP was 0.790. Moderate chemistry and strong radical recombination yielded TCP values of 0.713 and 0.703, respectively, whereas mild oxygen limitation reduced TCP to 0.276. Standard-dose-rate continuous delivery produced negligible oxygen depletion under null and moderate chemistry assumptions, while deliberately oxygen-limited standard-dose-rate cases showed reduced TCP.Significance.This exploratory framework provides a mechanistic treatment-course TCP platform for hypothesis testing in FLASH radiotherapy. It demonstrates how pulse microstructure and continuous standard-dose-rate delivery can be evaluated within the same published variable-timeformulation, while showing that FLASH TCP behavior depends on oxygen/radical kinetic assumptions, pulse structure, repair, and oxygen availability rather than being universally preserved or reduced.

Для цитирования: Lee Tae Kyu. Pulse-resolved tumor control probability modeling for FLASH radiotherapy using a variable-time treatment-course framework.. Physics in medicine and biology. 2026. DOI: 10.1088/1361-6560/ae944e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.