Detecting hypodiploidy with endoreduplication and masked hypodiploidy in B-cell acute lymphoblastic leukemia using multicolor flow cytometry.

Chaturvedi Anumeha, Shetty Dhanalaxmi, Ghogale Sitaram Gundu, Deshpande Nilesh, Badrinath Yajamanam, Chatterjee Gaurav, Girase Karishma, Sriram Harshini, Khanka Twinkle, Mishra Chetna, Dasgupta Niharika, Gujarathi Sejal Anil, Rajpal Sweta, Patkar Nikhil, Amare-Kadam Prathibha, Gujral Sumeet, Subramanian Papagudi Ganesan, Tembhare Prashant Ramesh

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Multicolor flow cytometry-based DNA-ploidy (MFC-ploidy) analysis is a simple, sensitive, and popular method for ploidy analysis in B-cell acute lymphoblastic leukemia (B-ALL). However, the utility of MFC-ploidy in the detection of B-ALL with endoreduplication or masked hypodiploidy has not been reported. Herein, we studied the patterns of MFC-ploidy assessment and its utility to detect B-ALL with hypodiploidy and endoreduplication.

METHODS

MFC-ploidy analysis was performed using FxCycle Violet-dye-based method, and cytogenetic ploidy was evaluated using chromosomal-counting and FISH analysis. A total of 20 B-ALL cases with endoreduplication were studied for the patterns of MFC-ploidy analysis and compared with 250 patients with hyperdiploidy and 11 cases with pure hypodiploidy.

RESULTS

All B-ALL with endoreduplication revealed two distinct peaks (populations) on MFC-ploidy analysis: the first (hypodiploid) peak (median-DNA-index [DI], 0.82; range, 0.6-0.95) and the second (hyperdiploid) peak with almost twice DI (median-DI, 1.53; range, 1.14-1.75). Cytogenetic findings were available in 19 cases and confirmed hypodiploidy with endoreduplication in 13/19 (68.4%) and only hypodiploidy in 3/19 cases. The remaining three cases showed hyperdiploid blasts in cytogenetic studies. Of these three, two cases had <10% blasts population with hypodiploidy. Thus, masked-hypodiploidy could be diagnosed correctly in 3/19 cases on MFC-ploidy analysis.

CONCLUSION

MFC-ploidy analysis shows a characteristic pattern of DNA-ploidy in samples with endoreduplication. It allows the distinction between samples with masked hypodiploidy from true hyperdiploidy. An integrated approach involving cytogenetic and MFC-ploidy detection is very helpful in the risk stratification of B-ALL in routine clinical practice.

Для цитирования: Chaturvedi Anumeha, Shetty Dhanalaxmi, Ghogale Sitaram Gundu, Deshpande Nilesh, Badrinath Yajamanam, Chatterjee Gaurav, Girase Karishma, Sriram Harshini, Khanka Twinkle, Mishra Chetna, Dasgupta Niharika, Gujarathi Sejal Anil, Rajpal Sweta, Patkar Nikhil, Amare-Kadam Prathibha, Gujral Sumeet, Subramanian Papagudi Ganesan, Tembhare Prashant Ramesh. Detecting hypodiploidy with endoreduplication and masked hypodiploidy in B-cell acute lymphoblastic leukemia using multicolor flow cytometry.. Cytometry. Part B, Clinical cytometry. 2022. DOI: 10.1002/cyto.b.22063.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.