m+Medelevator.RU
← Поиск публикаций
Medical physics · 2026

Real-world assessment of a deep learning neural network algorithm for prostate cancer detection in MRI using true de novo data.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shea Steven M, Wesolowski Michael, Hashem Abdulrahman, Goldberg Ari, Joyce Cara, Gupta Gopal, Grimm Robert, von Busch Heinrich, Lou Bin, Kamen Ali

Аннотация

BACKGROUND: Deep-learning neural network algorithms for detecting prostate cancer in MRI have proliferated in the literature. However, out of 30+ studies published since the PROSTATEx challenge, no studies tested the performance of their algorithm against using true external image data sets (studies came from an outside institution that did not supply any training data to the algorithm) while validating against MR-US fusion biopsy or whole-mount prostatectomy. Using true external data sets paints a much clearer picture of real-world clinical performance of an algorithm.

PURPOSE: This work will assess the performance of a published deep learning (DL) neural network algorithm to detect prostate cancer using external studies. The main difference from other studies is the combination of using only MR-US fusion biopsy results as a gold standard; using test data from an institution that did not supply any training data for this version of the algorithm (including studies acquired with an endorectal coil, which were not in the original training set); and comparing the performance of algorithm-generated regions-of-interest (ROIs) versus algorithm heat maps.

METHODS: Patients were included in the study if they had a prostate MRI with at least one radiologist-drawn target on MRI and underwent MR-US fusion biopsy where the target was sampled for pathological analysis. Patients were excluded if they had any history of prostate cancer treatment, had previously undergone MR-US fusion biopsy at our institution, were missing MRI acquisitions, had artifacts in image sets, or if the study had been shared for future algorithm development. MR image data was assessed using a DL research prototype (XProstate) from Siemens Healthineers that produced (a) ROIs in suspected cancer areas with a level of suspicion (LoS) score and (b) heat maps with LoS scores across the entire gland. The XProstate prototype had been trained with 2170 studies from eight different academic institutions. Clinical radiologist, XProstate ROI, and XProstate Heat Map scores were assessed with ROC analysis using pathology results from biopsy as a gold standard.

RESULTS: 202 unique patients were included for assessment of the XProstate research prototype. The ROC curve for the XProstate Heat Map LoS score generated the highest AUC (0.76, 95% CI: 0.70, 0.82) followed by clinical radiologist PI-RADS score (0.73, 95% CI: 0.68, 0.79) and by XProstate ROI LoS score (0.71, 95% CI: 0.65, 0.77). Neither the XProstate Heat Map (AUC difference = 0.03, 95% CI: -0.04, 0.10, p = 0.38) nor the XProstate ROI (AUC difference = -0.02, 95% CI: -0.09, 0.04, p = 0.43) was significantly different from the radiologist PI-RADS score.

CONCLUSIONS: The XProstate prototype demonstrated equivalent performance as clinical radiologists when presented with de novo cases that would mirror a real-world clinical deployment. The automatic ROI delineation more closely matched clinical radiologist performance when using a cutoff of PI-RADS 5 for annotating suspicious regions. Overall, the XProstate prototype provided reasonable clinical performance and this study demonstrated the need to assess Deep Learning prototypes with external institutional test data.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты