MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/advs.74861

Медицинская библиотека · Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026

Enzyme-Activated MRI for In Vivo Glucose Imaging via a Biodegradable Chromium Nanoprobe.

Xu Yan, Yang Weitao, Yun Yanjing, Wang Hui, Wu Zhuoyao, Yu Youyi, Zhang Bingbo

СтатьяПеревод в очереди

Аннотация

Non-invasive visualization of glucose metabolism in living organisms remains a major challenge, as existing techniques cannot specifically detect glucose molecules with deep-tissue penetration and without ionizing radiation. To overcome this, we developed an enzyme-activated magnetic resonance imaging strategy (eaMRI) using a biodegradable nanoprobe, CrGOx@Lip, that integrates endogenous Cr3+ ions with glucose oxidase for glucose-responsive imaging. Our approach leverages GOx not only as a catalytic engine to specifically oxidize glucose but also as a structural template to guide the in-situ synthesis of a potent MRI reporter (paramagnetic chromium gluconate). This design enables direct, specific amplification of MRI signals in proportion to local glucose concentration, achieving an 8.28-fold relaxivity increase. We validated this method for sensitive glucose mapping in vivo, including delineating Warburg-effect-driven tumors and quantifying pathological glucose accumulation in metabolic dysfunction-associated fatty liver disease (ΔSNR% = 18.51 ± 3.72 vs. 1.14 ± 1.39 in controls; p <0.001), and further demonstrated its utility in monitoring therapeutic efficacy via glucose-responsive signal changes. By synergizing enzymatic precision with nanomaterial engineering, our CrGOx@Lip-mediated eaMRI platform provides a glucose-specific, radiation-free, and non-invasive strategy for sensitive metabolic diagnostics in precision medicine.

Для цитирования: Xu Yan, Yang Weitao, Yun Yanjing, Wang Hui, Wu Zhuoyao, Yu Youyi, Zhang Bingbo. Enzyme-Activated MRI for In Vivo Glucose Imaging via a Biodegradable Chromium Nanoprobe.. Advanced science (Weinheim, Baden-Wurttemberg, Germany). 2026. DOI: 10.1002/advs.74861.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.