European journal of pediatric surgery : official journal of Austrian Association of Pediatric Surgery ... [et al] = Zeitschrift fur Kinderchirurgie · 2025
Feasibility and Challenges of Pyeloureteral Magnetic Anastomosis Device in Domestic Pigs: A Stepwise Approach with Extended Observation.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kubiak Rainer, Hornok Zita, Csukas Domokos, Ferencz Andrea, Cserni Tamas
Аннотация
OBJECTIVE: The pyeloureteral anastomosis remains the most challenging part of pyeloplasty. A purpose-built anastomotic device could simplify this step and potentially improve outcomes. The concept of a pyeloureteral magnetic anastomosis device (PUMA) was proven in minipigs, but only in short term. Our aim was to test the PUMA in domestic pigs and achieve a prolonged follow-up period.
METHODS: Five female domestic pigs underwent laparoscopy and ligation of the left ureter. Four weeks later, laparoscopic implantation of the PUMA was planned. Removal of the device and a retrograde contrast study were scheduled after another 4 weeks. The experiment was terminated when the animals could no longer be properly cared for due to their weight.
RESULTS: Due to unexpected smaller ureteric diameters, a modified PUMA could only be successfully inserted in pig number 3 (49 kg). Four weeks later, the device was found to be dislocated, but the anastomosis remained patent. After modifying the study protocol, the PUMA was successfully implanted in pigs number 4 (96 kg) and 5 (68 kg) 8 weeks after ureteric ligation. Pig 4 developed malignant hyperthermia and died. In pig 5, the magnets were removed 4 weeks later. After an additional 8 weeks, the animal reached 135 kg and was terminated. The anastomosis remained patent and preserved its diameter.
CONCLUSION: Despite limitations, our study successfully demonstrated that the PUMA can achieve a patent ureteric anastomosis in domestic pigs. This suggests a potential for minimally invasive ureteric anastomosis in clinical settings. Further research is needed to optimize the technique and validate its effectiveness in humans.
METHODS: Five female domestic pigs underwent laparoscopy and ligation of the left ureter. Four weeks later, laparoscopic implantation of the PUMA was planned. Removal of the device and a retrograde contrast study were scheduled after another 4 weeks. The experiment was terminated when the animals could no longer be properly cared for due to their weight.
RESULTS: Due to unexpected smaller ureteric diameters, a modified PUMA could only be successfully inserted in pig number 3 (49 kg). Four weeks later, the device was found to be dislocated, but the anastomosis remained patent. After modifying the study protocol, the PUMA was successfully implanted in pigs number 4 (96 kg) and 5 (68 kg) 8 weeks after ureteric ligation. Pig 4 developed malignant hyperthermia and died. In pig 5, the magnets were removed 4 weeks later. After an additional 8 weeks, the animal reached 135 kg and was terminated. The anastomosis remained patent and preserved its diameter.
CONCLUSION: Despite limitations, our study successfully demonstrated that the PUMA can achieve a patent ureteric anastomosis in domestic pigs. This suggests a potential for minimally invasive ureteric anastomosis in clinical settings. Further research is needed to optimize the technique and validate its effectiveness in humans.