MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2025.111205

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2025

Long-term prediction of radiation-induced optic neuropathy: A mixed-effects analysis of visual field kinetics following proton therapy.

Pham Thao-Nguyen, Mathis Thibaud, Azemar Nathan, Vela Anthony, Quintyn Jean-Claude, Thariat Juliette

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Radiation-induced optic neuropathy (RION) is a rare but serious complication of radiotherapy, leading to progressive vision loss. The temporal dynamics of RION are poorly understood, limiting effective monitoring and intervention. We developed a predictive mixed-effects model of visual field deterioration, a sensitive surrogate marker for clinically-reported RION, by integrating longitudinal clinical and dosimetric data, to anticipate long-term visual outcomes.

METHODS

Out of a prospective database of 238 patients, 179 eyes from 105 patients treated with pencil beam scanning proton therapy were included. All selected eyes had no significant visual field deficit at baseline, defined as a mean visual sensitivity loss better than -6 dB. Baseline clinical characteristics, detailed dosimetric data, and longitudinal visual field assessments were collected. Temporal changes in mean visual sensitivity were analyzed using feature selection through random forest models and linear regression. A nonlinear mixed-effects model was then developed to predict the trajectory of visual field deterioration over time.

RESULTS

Visual field deterioration progressed significantly over time, with a quadratic model best capturing the kinetics. Mean sensitivity loss accelerated with increasing age and clinical target volume. Incorporating the full dose-volume histogram, the volume of the optic chiasma received at least 40 Gy (V40/chiasma), improved model performance. Simulation based on this model showed that the probability of RION increased sharply over time: 4.6 % at 2 years, and 28.3 % at 5 years.

CONCLUSION

This model confirms and expands upon prior work by showing that clinical factors can outweigh dosimetric ones in predicting RION progression. Our model was capable of predicting long-term visual outcomes even in patients with limited follow-up.

Для цитирования: Pham Thao-Nguyen, Mathis Thibaud, Azemar Nathan, Vela Anthony, Quintyn Jean-Claude, Thariat Juliette. Long-term prediction of radiation-induced optic neuropathy: A mixed-effects analysis of visual field kinetics following proton therapy.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2025. DOI: 10.1016/j.radonc.2025.111205.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.