m+Medelevator.RU
← Поиск публикаций
Revista espanola de enfermedades digestivas · 2014

Factors related to the effectiveness of variable stiffness colonoscope: results of a multivariate analysis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sola-Vera Javier, Uceda Francisco, Brotons Alicia, Sáez Jesús, Girona Eva, Pérez Estefanía, Picó María Dolores, Grau Concepción, Vázquez Narciso

Аннотация

BACKGROUND: Various studies and two meta-analysis have shown that a variable stiffness colonoscope improves cecal intubation rate. However, there are few studies on how this colonoscope should be used.

OBJECTIVE: The aim of this study was to identify factors related to the advancement of the colonoscope when the variable stiffness function is activated.

METHODS: Prospective study enrolling consecutive patients referred for colonoscopy. The variable stiffness colonoscope (Olympus CF-H180DI/L®) was used. We performed univariate and multivariate analyses of factors associated with the success of the variable stiffness function.

RESULTS: After the data inclusion period, 260 patients were analyzed. The variable stiffness function was used most in the proximal colon segments (ascending and transverse colon 85%; descending/sigmoid colon 15.2%). The body mass index was lower in patients in whom the endoscope advanced after activating the variable stiffness than those in which it could not be advanced (25.9 + or - 4.8 vs. 28.3 + or - 5.4 kg/m2, p = 0.009). The endoscope advanced less frequently when the stiffness function was activated in the ascending colon versus activation in other segments of the colon (25% vs. 64.5% ascending colon vs. other segments; p < 0.05). In the multivariate analysis, only the colon segment in which the variable stiffness was activated was an independent predictor of advancement of the colonoscope.

CONCLUSIONS: The variable stiffness function is effective, allowing the colonoscope advancement especially when applied in the transverse colon, descending colon and sigmoid. However, when used in the ascending colon it has a lower effectiveness.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты