MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.rceng.2025.502333

Медицинская библиотека · Revista clinica espanola · 2025

The contribution of PET/MRI in benign/malignant nodule separation in thyroid incidentalomas detected in FDG PET/CT imaging.

Nazari A, Sager S, Schenke S, Uslu Beşli L, Samancı C, Öztürk T, Sayman H B

СтатьяПеревод в очереди

Аннотация

INTRODUCTION AND

OBJECTIVES

Incidentalomas of the thyroid gland are frequently observed in oncological patients undergoing FDG PET/CT imaging for staging or treatment response assessment. This study aims to investigate the utility of SUVmax and ADC values measured by PET/MRI in distinguishing between benign and malignant thyroid nodules.

MATERIALS AND

METHODS

We selected 108 patients (72 females, 36 males; mean age 54 ± 12 years) who underwent routine oncological FDG PET/CT scans for staging or treatment response assessment, with nodule sizes greater than 1 cm. A one-bed neck PET/MRI scan followed the whole-body PET/CT. SUVmax values were measured, and ADC maps were created using DWI with b factors of 50 and 1000 s/mm2. SUVmax and ADC values were correlated with FNAC results.

RESULTS

FNAC results revealed 76 (70.4%) benign and 32 (29.6%) malignant nodules among the 108 patients. The mean SUVmax of malignant nodules was significantly higher than that of benign nodules (10.6 ± 8.3 vs. 5.94 ± 5.2, p < 0.001). Similarly, the mean ADC value was lower in malignant nodules compared to benign ones (1.4 ± 0.6 × 10-3 mm2/s vs. 1.8 ± 0.4 × 10-3 mm2/s; p < 0.001). A significant but weak correlation was found between FNAC results and mean SUVmax (r = 0.335), as well as a significant weak negative correlation with mean ADC values (r = -0.355). Using a cut-off value of 6 for SUVmax and 1.56 × 10-3 mm2/s for ADC, the sensitivity, specificity, and accuracy for SUVmax were 68.7%, 73.6%, and 72.1%, respectively, while for ADC, they were 71.8%, 69.7%, and 70.4%, respectively. The PET/MRI system demonstrated a relative sensitivity, specificity, accuracy, PPV, and NPV of 90.62%, 51.32%, 62.96%, 43.94%, and 92.86%.

CONCLUSION

This study is one of the first in the literature to explore the use of FDG PET/MRI, a single-stop device, in distinguishing between benign and malignant thyroid nodules with high sensitivity and NPV.

Для цитирования: Nazari A, Sager S, Schenke S, Uslu Beşli L, Samancı C, Öztürk T, Sayman H B. The contribution of PET/MRI in benign/malignant nodule separation in thyroid incidentalomas detected in FDG PET/CT imaging.. Revista clinica espanola. 2025. DOI: 10.1016/j.rceng.2025.502333.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.