Reducing the Number of Unnecessary Thyroid Biopsies While Improving Diagnostic Accuracy: Toward the "Right" TIRADS.

Grani Giorgio, Lamartina Livia, Ascoli Valeria, Bosco Daniela, Biffoni Marco, Giacomelli Laura, Maranghi Marianna, Falcone Rosa, Ramundo Valeria, Cantisani Vito, Filetti Sebastiano, Durante Cosimo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

CONTEXT: The prevalence of thyroid nodules in the general population is increasingly high, and at least half of those biopsied prove to be benign. Sonographic risk-stratification systems are being proposed as "rule-out" tests that can identify nodules that do not require fine-needle aspiration (FNA) cytology.

OBJECTIVE

To comparatively assess the performances of five internationally endorsed sonographic classification systems [those of the American Thyroid Association, the American Association of Clinical Endocrinologists, the American College of Radiology (ACR), the European Thyroid Association, and the Korean Society of Thyroid Radiology] in identifying nodules whose FNAs can be safely deferred and to estimate their negative predictive values (NPVs).

DESIGN

Prospective study of thyroid nodules referred for FNA.

SETTING

Single academic referral center.

PATIENTS: Four hundred seventy-seven patients (358 females, 75.2%); mean (SD) age, 55.9 (13.9) years.

MAIN OUTCOME MEASURES: Number of biopsies classified as unnecessary, false-negative rate (FNR), sensitivity, specificity, predictive values, and diagnostic ORs for each system.

RESULTS

Application of the systems' FNA criteria would have reduced the number of biopsies performed by 17.1% to 53.4%. The ACR Thyroid Imaging Reporting and Data System (TIRADS) allowed the largest reduction (268 of 502) with the lowest FNR (NPV, 97.8%; 95% CI, 95.2% to 99.2%). Except for the Korean Society of Thyroid Radiology TIRADS, all other systems exhibited significant discriminatory performance but produced significantly smaller reductions in the number of procedures.

CONCLUSIONS

Internationally endorsed sonographic risk stratification systems vary widely in their ability to reduce the number of unnecessary thyroid nodule FNAs. The ACR TIRADS outperformed the others, classifying more than half the biopsies as unnecessary with a FNR of 2.2%.

Для цитирования: Grani Giorgio, Lamartina Livia, Ascoli Valeria, Bosco Daniela, Biffoni Marco, Giacomelli Laura, Maranghi Marianna, Falcone Rosa, Ramundo Valeria, Cantisani Vito, Filetti Sebastiano, Durante Cosimo. Reducing the Number of Unnecessary Thyroid Biopsies While Improving Diagnostic Accuracy: Toward the "Right" TIRADS.. The Journal of clinical endocrinology and metabolism. 2019. DOI: 10.1210/jc.2018-01674.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.