MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0167-8140(93)90021-y

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 1993

Effect of intersource spacing on local control and complications in brachytherapy of mobile tongue and floor of mouth.

Simon J M, Mazeron J J, Pohar S, Le Péchoux C, Crook J M, Grimard L, Piedbois P, Le Bourgeois J P, Pierquin B

СтатьяПеревод в очереди

Аннотация

From 1971 to 1988, 133 T1 and 141 T2 biopsy-proven squamous cell carcinomas of mobile tongue and floor of mouth were definitively managed by Iridium-192. Implantations were performed using either guide gutters or afterloading plastic catheters. The prescribed dose at the reference isodose (85% of the basal dose rate, Paris system) was 60-70 Gy. Total dose was not adjusted to dose rate or tumor volume. Results of the 274 implants have been analysed to look for a possible influence of intersource spacing on local control and necrosis. Follow up for patients free of local recurrence is 1-180 months with median of 35 months. The 274 tumors were divided into two groups according to intersource spacing: 9-14 mm (n = 204), and 15-20 mm (n = 70). At 5 years, the estimated local control (Kaplan Meier) was 86% and 76%; respectively (p = 0.13); the necrosis rate was 33% and 46%, respectively (p = 0.04). Multivariate analysis shows that dose and activity of wires were significantly related to local control, while only tumor site was predictive of necrosis; there was a non-statistically significant relationship between intersource spacing of wires and local control (p = 0.055). When considering only patients with oral tongue cancers, necrosis was significantly related to activity of wires (p = 0.013), and there was a non-significant trend to a relationship between necrosis and intersource spacing (p = 0.066) and tumor diameter (p = 0.065). For patients with floor of mouth cancer, none of these factors was significantly related to necrosis.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Simon J M, Mazeron J J, Pohar S, Le Péchoux C, Crook J M, Grimard L, Piedbois P, Le Bourgeois J P, Pierquin B. Effect of intersource spacing on local control and complications in brachytherapy of mobile tongue and floor of mouth.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 1993. DOI: 10.1016/0167-8140(93)90021-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.