MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/his.70272

Медицинская библиотека · Histopathology · 2026

Visual steatosis assessment: method-dependent variation and systematically higher estimates compared with AI measurement.

Nazli Saadiya, Shaaban Abdelrahman, Patil Ameya, Smith Lindsey, Stetzik Lucas, Hasan Bashar, Elhalaby Rofyda, DaCosta Adilson, Sivasubramaniam Priya, Park Byoung Uk, Krishna Murli, Salomao Marcela, Pai Rish, Smith Maxwell, Allende Daniela, Hartley Christopher P, Lee Hee Eun, Chen Zongming Eric, Matkowskyj Kristina A, Graham Rondell P, Moreira Roger K

СтатьяПеревод в очереди

Аннотация

AIMS: Despite its clinical importance, histological steatosis assessment remains poorly standardized and highly variable among pathologists. We examined determinants of this variability by comparing pathologist estimates with quantitative artificial intelligence (AI) based measurements.

METHODS AND

RESULTS

Ten experienced liver pathologists from four institutions evaluated a limited set of 20 permanent H&E-stained whole-slide images (WSIs) from metabolic dysfunction-associated steatotic liver disease (MASLD) cases (10 core biopsies, 7 wedge biopsies and 3 resections) and 6 additional 500 × 500-μm image fields from separate permanent H&E-stained cases selected to represent varying droplet compositions. The WSIs spanned the full spectrum of steatosis severity. Assessments used four phases: default method, steatosis proportionate area (SPA), percentage of hepatocytes containing fat (%HCF) and Banff large-droplet criteria. Image fields were also assessed using no size cut-off or cut-offs based on hepatocyte, nuclear or 2-3× nuclear size. AI models quantified SPA, %HCF and droplet size for comparison with pathologists' assessments. Pathologists differed substantially in terminology, droplet-size definitions and quantification methods. Method choice (SPA vs. %HCF) was a major determinant of estimate dispersion and discrepancy from AI measurements. Visual estimates exceeded AI quantification by 1.4-3.6×. Pathologists' SPA estimates were increasingly higher than the corresponding AI measurements with increasing burden of droplets with area below 50 μm2, whereas, in exploratory analysis, %HCF estimates remained relatively stable relative to the corresponding AI measurements. Mixed-effects calibration equations were derived to relate visual and digital assessment scales.

CONCLUSION

Steatosis assessment lacks standardized terminology and measurement practices. SPA and %HCF are conceptually distinct, and their interchangeable use amplifies discrepancies, particularly in small-droplet-rich cases. These findings support standardized, AI-compatible quantification; the exploratory conversion equations require independent validation before clinical application.

Для цитирования: Nazli Saadiya, Shaaban Abdelrahman, Patil Ameya, Smith Lindsey, Stetzik Lucas, Hasan Bashar, Elhalaby Rofyda, DaCosta Adilson, Sivasubramaniam Priya, Park Byoung Uk, Krishna Murli, Salomao Marcela, Pai Rish, Smith Maxwell, Allende Daniela, Hartley Christopher P, Lee Hee Eun, Chen Zongming Eric, Matkowskyj Kristina A, Graham Rondell P, Moreira Roger K. Visual steatosis assessment: method-dependent variation and systematically higher estimates compared with AI measurement.. Histopathology. 2026. DOI: 10.1111/his.70272.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.