m+Medelevator.RU
← Поиск публикаций
Journal of endourology · 2024

Assessment of Holmium:YAG, Pulsed-Thulium:YAG and Thulium Fiber Lasers for Urinary Stone Ablation. In Vitro Study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sierra Alba, Panthier Frederic, Castillo Esther, Mercadé Asier, Peri Lluís, Alcaraz Antonio, Traxer Olivier, López Juan Manuel, Luque Maria Pilar

Аннотация

Objective: To evaluate the ablation speed (AS), laser efficiency and direct thermal lesions during urinary stone lithotripsy with the current available laser technologies: Holmium:YAG (Ho:YAG), pulsed-Thulium:YAG (p-Tm:YAG) and thulium fiber laser (TFL) in vitro using different laser settings. Materials and Methods: Ho:YAG, p-Tm:YAG, and TFL laser system were used in an in vitro ureteral model with a volume of 125 mm3 Begostone. The following parameters were tested across all laser devices: 0.6J/10 Hz (6 W), 0.6 J/20 Hz (12 W), 1.5 J/10 Hz (15 W), and 1.5 J/20 Hz (30 W), employing short pulse width for all lasers and long pulse width for Ho:YAG and p-Tm:YAG. Ten participants conducted the experimental setup during 3-minutes laser on time, combining the laser technology, settings, and pulse widths, with a total of 20 different combinations. The efficiency, AS and ureteral damage resulting from each intervention were analyzed. Results: p-Tm:YAG and TFL demonstrated significantly higher efficiency compared with Ho:YAG (0.049 ± 0.02 Δgr/KJ and 0.042 ± 0.01 Δgr/KJ vs 0.029 ± 0.01 Δgr/KJ; p < 0.05). In all laser sources, as the power increases, the AS also increases (p < 0.05). Furthermore, only at high-energy settings (1.5 J) higher frequency led to increase AS (p < 0.05). Both, p-Tm:YAG and TFL exhibited higher AS compared to Ho:YAG (0.64 ± 0.33 Δgr/s and 0.62 ± 0.31 Δgr/s vs 0.44 ± 0.22 Δgr/s; p < 0.05). Regarding ureteral injuries, as the power increases, there is a higher chance of ureteral damage (p = 0.031). No differences were observed between laser technologies (p = 0.828). Conclusions: Both, p-Tm:YAG and TFL exhibited superior performances during laser lithotripsy compared with Ho:YAG, as they demonstrated higher efficiency and ablation speed. Thermal damage did not appear to be associated with specific laser equipment, but higher grades of lesions are described by increasing power.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты