OBJECTIVE

The purpose of this study was to compare 3D volume isotropic turbo spin-echo acquisition (VISTA) MRI with and without fat suppression for use in evaluating ligaments, menisci, and cartilage.

MATERIALS AND

METHODS

Two radiologists retrospectively and independently reviewed 71 MRI studies. Each study consisted of 3D intermediate-weighted VISTA images with fat suppression and without fat suppression. The presence of tears of the anterior cruciate and posterior cruciate ligaments, tears of the medial and lateral menisci, and cartilaginous defects was evaluated. Arthroscopic surgical findings were used as the standard of reference. Statistical analysis was performed to calculate the sensitivity, specificity, and accuracy of the two methods.

RESULTS

Mean specificity and accuracy for medial meniscal tears were significantly higher with VISTA (specificity, 95.0%; accuracy, 94.4%) than with fat-suppressed VISTA (FS-VISTA) (specificity, 81.3%; accuracy, 85.9%), and the difference was statistically significant (specificity, p = 0.003; accuracy, p = 0.004). Mean specificity for cartilaginous defects was also significantly higher with VISTA than with FS-VISTA (99.1% vs 96.8%, p = 0.039). There were no other significant differences between the two methods.

CONCLUSION

Three-dimensional VISTA MRI has higher specificity than FS-VISTA imaging for evaluation of medial meniscal tears and cartilaginous defects.

Для цитирования: Lee Ji Hyun, Yoon Young Cheol, Park Ki Jeong, Wang Joon Ho. Diagnosis of Internal Derangement of the Knee: Volume Isotropic Turbo Spin-Echo Acquisition MRI With Fat Suppression Versus Without Fat Suppression.. AJR. American journal of roentgenology. 2017. DOI: 10.2214/ajr.16.17217.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.