m+Medelevator.RU
← Поиск публикаций
Modern rheumatology case reports · 2025

Successful treatment of recurrent haemarthrosis after total knee arthroplasty using genicular artery embolisation in a patient with rheumatoid arthritis.

СтатьяКлинический случайНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Iiboshi Mayu, Mizuhara Hiroyasu, Makabe Kenta, Omata Yasunori, Watadani Takeyuki, Tanaka Sakae, Matsumoto Takumi

Аннотация

Recurrent haemarthrosis after total knee arthroplasty (TKA) is a rare but challenging complication, with an incidence ranging from 0.3% to 1.6%. Conservative treatment, including rest, joint aspiration, and oral tranexamic acid, is often the first-line approach, but approximately two-thirds of cases require more invasive procedures. Genicular artery embolisation (GAE) has emerged as a promising alternative to synovectomy for refractory cases, offering high success rates with fewer complications. While most reports of GAE for recurrent haemarthrosis focus on patients with osteoarthritis, data on its use in patients with rheumatoid arthritis (RA) are scarce. We report a case of a 79-year-old woman with RA who presented with recurrent haemarthrosis 11 years after TKA. Despite conservative treatment, her haemarthrosis persisted. Angiography revealed three hypervascular areas supplied by branches of the superior lateral, superior medial, and middle genicular arteries. Embolisation was successfully performed using gelatin sponge, resulting in complete symptom resolution without recurrence at the 2-year follow-up. This case highlights the potential of GAE as a viable treatment option for recurrent haemarthrosis in patients with RA, particularly those with multiple bleeding sites or when synovectomy is unsuccessful or impractical. Careful evaluation from multiple angiographic angles is crucial to detect all bleeding sources, especially in post-TKA cases where metal implants may obscure vascular regions. Although further studies are needed, GAE may represent a safe and effective alternative for managing recurrent haemarthrosis in patients with RA.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты