Biphasic Interpositional Allograft for Rotator Cuff Repair Augmentation Is Safe in an Ovine Model.

Credille Kevin T, Wang Zachary R C, Horner Nolan S, Regan Daniel P, Gadomski Benjamin C, Easley Jeremiah T, Garrigues Grant E, Yanke Adam B

Рандомизированное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To perform a preclinical histologic assessment of a biphasic acellular interpositional cancellous allograft in an ovine model of rotator cuff repair (RCR) designed to better understand its safety profile and effects on tendon healing after RCR.

METHODS

Thirty skeletally mature sheep with clinically normal shoulders with an artificially created degenerative infraspinatus tendon tear were randomized to control and treatment groups. Animals were euthanized at 3 weeks, 6 weeks, and 12 weeks. After gross dissection, rotator cuff specimens were fixed with formalin and polymerized for sectioning and staining. Blinded histologic scores evaluated inflammatory cell infiltrates, signs of degradation, particulate debris, collagen arrangement, neovascularization, and enthesis qualitative measures.

RESULTS

There were no treatment specimens that exhibited histologic signs of a significant infection, inflammatory infiltrate, or foreign body reaction such as granuloma or fibrous capsule formation. Histologic scores in all categories were not significantly different at all time points, including the primary end point mean cumulative inflammatory score (control: 3.66 ± 1.21 vs treated: 4.33 ± 1.51, P = .42), when comparing the treatment and control RCR groups. In general, the degree of tendon healing and host tissue response was essentially equivalent between the 2 groups with observation of low overall levels of inflammation and progressive improvements in collagen organization, reduced tenocyte activity, and fibrocartilaginous enthesis reformation.

CONCLUSIONS

This histologic study demonstrated the use of a biphasic interpositional allograft for RCR augmentation in an ovine model does not generate an inflammatory response or foreign body reaction. Use of the biphasic interpositional allograft resulted in a histological profile that was essentially equivalent to that of a standard RCR at 3-, 6-, and 12-week postoperative timepoints. These findings suggest that a biphasic interpositional allograft is safe for further clinical investigation in humans before broader clinical application.

CLINICAL RELEVANCE: Patch augmentation of RCR is a popular technique that has shown clinical success in improving the likelihood of a successful repair in patients at elevated risk for retear. Newer augmentation technologies are being developed to address the biology at the interface between the bone and soft tissue where failure typically occurs.

Для цитирования: Credille Kevin T, Wang Zachary R C, Horner Nolan S, Regan Daniel P, Gadomski Benjamin C, Easley Jeremiah T, Garrigues Grant E, Yanke Adam B. Biphasic Interpositional Allograft for Rotator Cuff Repair Augmentation Is Safe in an Ovine Model.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2023. DOI: 10.1016/j.arthro.2023.03.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.