MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Acta orthopaedica Belgica · 2011

Early failure of a knee replacement in a neuropathic joint. A case report.

Yasin Mohammed N, Charalambous Charalambos P, Mills Simon P, Phaltankar Padmanabh M, Nurron Richard W

Клинический случайСтатьяПеревод в очереди

Аннотация

Total knee arthroplasty in neuropathic (Charcot) joints is technically demanding. Most studies report significant improvement in knee function, despite a high incidence of complications. We present a case of idiopathic, unilateral neuropathic arthropathy of the knee treated with a modular stemmed, constrained total knee arthroplasty. Unscrewing of the stem of the tibial component was detected a year following surgery. The tibial component was revised to a custom made monobloc stemmed implant. Satisfactory knee function was noted at short-term follow-up. This case highlights a potential problem of using modular long-stem implants in neuropathic joints and emphasises the need for close follow-up of these difficult cases.

Для цитирования: Yasin Mohammed N, Charalambous Charalambos P, Mills Simon P, Phaltankar Padmanabh M, Nurron Richard W. Early failure of a knee replacement in a neuropathic joint. A case report.. Acta orthopaedica Belgica. 2011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.