DOI 10.12200/j.issn.1003-0034.2023.02.012
[Olecranon osteotomy approach for Dubberley type Ⅲ coronal fractures of the distal humerus].
Аннотация
OBJECTIVE
To retrospectively analyze the clinical efficacy of olecranon osteotomy approach in the treatment of Dubberley type Ⅲ coronal fractures of the distal humerus and summarize the treatment experience.
METHODS
From January 2016 to June 2020, 17 patients (5 males and 12 females) with Dubberley type Ⅲ coronal fractures of the distal humerus were treated by olecranon osteotomy approach. The age ranged from 37 to78 years old with an average of (58.5±12.9) years old. According to Dubberley classification, there were 5 cases of type Ⅲ A and 12 cases of type Ⅲ B. The curative effect was evaluated using the Borberg-Morrey elbow function score. The flexion, extension and rotation range of motion of the elbow joint, complications and postoperative imaging evaluation were recorded.
RESULTS
All the 17 patients got bony union. The follow-up time ranged from 12 to 33 months with an average of (15.6±5.6) months. There was 1 case of ischemic necrosis of capitulum humeri, 2 cases of traumatic arthritis and 1 case of heterotopic ossification, 1 case of malunion of fracture. The range of motion was (114.80±19.50) °. The Broberg-Morrey score was 85.3±8.2, excellent in 5 cases, good in 9 cases, fair in 3 cases and poor in 0 case.
CONCLUSION
Through olecranon osteotomy approach, the articular surface of distal humerus could be fully exposed, and the operation is convenient. Anatomical reduction and rigid fixation of the articular surface of distal humerus are the key factors for the succesful outcome.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.