MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/brs.0000000000005818

Медицинская библиотека · Spine · 2026

T4-L1PA Mismatch Predicts Mechanical Revision After Multilevel Fusion to the Upper Lumbar and Lower Thoracic Spine.

Maurer Steven M, Ortiz Simon, Rocha Torres Pedro Augusto, Wimmer Julia, Folkerts Tom, Verna Bruno, Shue Jennifer, Loibl Markus, Fekete Tamás F, Pumberger Matthias, Girardi Federico P, Cammisa Frank P, Sama Andrew A, Hughes Alexander P, Burkhard Marco D

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Retrospective single-center cohort study.

OBJECTIVE

To investigate whether postoperative T4-L1PA mismatch (T4 pelvic angle minus L1 pelvic angle) predicts mechanical revision within 5 years after multilevel fusion to the upper lumbar and lower thoracic spine, versus other alignment parameters.

SUMMARY OF BACKGROUND DATA: T4-L1PA mismatch is an established predictor of mechanical failure after upper thoracic fusion to the sacropelvis. Its value in lower thoracic spine and upper lumbar constructs remains unclear.

METHODS

We retrospectively analyzed 204 patients who underwent posterior spinal fusion of 3 to 10 instrumented levels (upper instrumented vertebra [UIV] T8-L3) with distal fixation to the sacrum or ilium (2006-2024). Alignment was assessed preoperatively, at the first postoperative timepoint, and at 1 year: T4-L1PA mismatch, PI-LL mismatch, sagittal vertical axis, L1PA deviation, lordosis distribution index, and distal lordosis. The primary outcome was mechanical revision within 5 years. Cox regression, ROC, Kaplan-Meier, and combined-risk analyses were performed.

RESULTS

Thirty-three patients (16.2%) underwent mechanical revision within 5 years. On first postoperative radiographs, T4-L1PA mismatch predicted revision (hazard ratio [HR] 1.10, P=0.012), as did PI-LL (HR 1.03, P=0.027). Adjusted for PI-LL, age, and levels fused, T4-L1PA remained significant (HR 1.09, P=0.028) while PI-LL did not (P=0.070). At 1 year (n=148, 16 events), T4-L1PA had an HR of 1.17 (P=0.001; PI-LL P=0.171). Other parameters were non-significant. Five-year cumulative revision incidence rose from 6% with neither parameter malaligned to 19% with one and 39% with both (log-rank P=0.003).

CONCLUSIONS

Postoperative T4-L1PA mismatch was the most consistent alignment predictor of mechanical revision over 5 years in thoracolumbar and upper lumbar fusions (UIV T8-L3) to the sacropelvis and remained independently prognostic at 1 year, with most revisions attributable to proximal junctional failure. PI-LL contributed early risk but weakened over time. Combined assessment identified a high-risk subgroup.

Для цитирования: Maurer Steven M, Ortiz Simon, Rocha Torres Pedro Augusto, Wimmer Julia, Folkerts Tom, Verna Bruno, Shue Jennifer, Loibl Markus, Fekete Tamás F, Pumberger Matthias, Girardi Federico P, Cammisa Frank P, Sama Andrew A, Hughes Alexander P, Burkhard Marco D. T4-L1PA Mismatch Predicts Mechanical Revision After Multilevel Fusion to the Upper Lumbar and Lower Thoracic Spine.. Spine. 2026. DOI: 10.1097/brs.0000000000005818.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.