DOI 10.1007/s00234-026-04195-2
The value of "Black-Bone" MR imaging in pediatric spondylolysis: impact on diagnostic confidence and accuracy in experienced and non-experienced readers.
Аннотация
INTRODUCTION
Lumbar spondylolysis is a common cause of low back pain in adolescents, yet early and confident diagnosis often requires CT, exposing patients to radiation. The Black-Bone (BB) MR sequence is a 3D low-flip-angle gradient-echo (GRE) acquisition designed to enhance bone-soft tissue contrast. This study assessed whether adding BB to a standard pediatric lumbar MRI protocol improves diagnostic accuracy, interreader-agreement, and confidence.
METHODS
Forty-four adolescents (mean age, 12 years; 23 girls, 21 boys) with suspected spondylolysis underwent lumbar MRI including BB, with radiographs and/or CT as reference standard. Thirty patients had confirmed spondylolysis and 14 served as controls. Four blinded readers (2 senior neuroradiologists, 2 residents) independently reviewed all cases twice: first with standard MRI only, then with BB included. Readers scored each pars interarticularis level and side (0 = negative, 1 = probable, 2 = definite). Interrater agreement (weighted Cohen's κ), sensitivity, specificity, PPV, NPV, and accuracy were calculated.
RESULTS
BB improved interrater agreement across all pairs (κ 0.81-0.93 vs. 0.59-0.82 pre-BB). Sensitivity increased for all readers (+ 5-12% points), while specificity remained high (0.89-1.00). PPV was consistently excellent (0.93-1.00), and NPV improved with BB (0.83-0.87 vs. 0.75-0.83 pre-BB). Ambiguous ratings dropped from 58 pre-BB to 5 post-BB, resolving > 90% of indeterminate assessments. Accuracy increased by approximately 2-5% points, whereas diagnostic confidence showed a larger improvement.
CONCLUSION
Incorporating BB into pediatric lumbar MRI protocols improved interreader agreement and diagnostic confidence while markedly reducing equivocal interpretations. Although diagnostic performance metrics improved, these findings should be interpreted cautiously given the limited CT correlation. BB may represent a practical radiation-free adjunct to standard MRI for evaluating suspected pediatric spondylolysis.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.