MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/art.42368

Медицинская библиотека · Arthritis & rheumatology (Hoboken, N.J.) · 2023

Reliability and Diagnostic Accuracy of Radiography for the Diagnosis of Calcium Pyrophosphate Deposition: Performance of the Novel Definitions Developed by an International Multidisciplinary Working Group.

Sirotti Silvia, Becce Fabio, Sconfienza Luca M, Terslev Lene, Naredo Esperanza, Zufferey Pascal, Pineda Carlos, Gutierrez Marwin, Adinolfi Antonella, Serban Teodora, MacCarter Daryl, Mouterde Gael, Zanetti Anna, Scanu Anna, Möller Ingrid, Novo-Rivas Ulrike, Largo Raquel, Sarzi-Puttini Piercarlo, Abhishek Abhishek, Choi Hyon K, Dalbeth Nicola, Pascart Tristan, Tedeschi Sara K, D'Agostino Maria-Antonietta, Iagnocco Annamaria, Keen Helen I, Scirè Carlo A, Filippou Georgios

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

OBJECTIVE

To assess the reliability and diagnostic accuracy of new radiographic imaging definitions developed by an international multidisciplinary working group for identification of calcium pyrophosphate deposition (CPPD).

METHODS

Patients with knee osteoarthritis scheduled for knee replacement were enrolled. Two radiologists and 2 rheumatologists twice assessed radiographic images for presence or absence of CPPD in menisci, hyaline cartilage, tendons, joint capsule, or synovial membrane, using the new definitions. In case of disagreement, a consensus decision was made and considered for the assessment of diagnostic performance. Histologic examination of postsurgical specimens under compensated polarized light microscopy was the reference standard. Prevalence-adjusted bias-adjusted kappa values were used to assess reliability, and diagnostic performance statistics were calculated.

RESULTS

Sixty-seven patients were enrolled for the reliability study. The interobserver reliability was substantial in most of the assessed structures when considering all 4 readers (κ range 0.59-0.90), substantial to almost perfect among radiologists (κ range 0.70-0.91), and moderate to almost perfect among rheumatologists (κ range 0.46-0.88). The intraobserver reliability was substantial to almost perfect for all the observers (κ range 0.70-1). Fifty-one patients were included in the accuracy study. Radiography demonstrated an overall specificity of 92% for CPPD, but sensitivity remained low for all sites and for the overall diagnosis (54%).

CONCLUSION

The new radiographic definitions of CPPD are highly specific against the gold standard of histologic diagnosis. When the described radiographic findings are present, these definitions allow for a definitive diagnosis of CPPD, rather than other calcium-containing crystal depositions; however, a negative radiographic finding does not exclude the diagnosis.

Для цитирования: Sirotti Silvia, Becce Fabio, Sconfienza Luca M, Terslev Lene, Naredo Esperanza, Zufferey Pascal, Pineda Carlos, Gutierrez Marwin, Adinolfi Antonella, Serban Teodora, MacCarter Daryl, Mouterde Gael, Zanetti Anna, Scanu Anna, Möller Ingrid, Novo-Rivas Ulrike, Largo Raquel, Sarzi-Puttini Piercarlo, Abhishek Abhishek, Choi Hyon K, Dalbeth Nicola, Pascart Tristan, Tedeschi Sara K, D'Agostino Maria-Antonietta, Iagnocco Annamaria, Keen Helen I, Scirè Carlo A, Filippou Georgios. Reliability and Diagnostic Accuracy of Radiography for the Diagnosis of Calcium Pyrophosphate Deposition: Performance of the Novel Definitions Developed by an International Multidisciplinary Working Group.. Arthritis & rheumatology (Hoboken, N.J.). 2023. DOI: 10.1002/art.42368.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.