MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2460/ajvr.72.7.905

Медицинская библиотека · American journal of veterinary research · 2011

Effects of body position, imaging plane, and observer on computed tomographic measurements of the lumbosacral intervertebral foraminal area in dogs.

Higgins Brent M, Cripps Peter J, Baker Martin, Moore Lee, Penrose Fay E, McConnell James F

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate effects of imaging plane, flexion and extension, patient weight, and observer on computed tomographic (CT) image measurements of the area of the lumbosacral (L7-S1) intervertebral foramen (LSIF) in dogs.

SAMPLE: 12 dog cadavers (2 were excluded because of foraminal stenosis).

PROCEDURES: In each cadaver, sagittal, sagittal oblique, transverse oblique, and double oblique CT images were obtained at 3 zones (entrance, middle, and exit zones) of the region of the lateral lumbar spinal canal that comprises the LSIF while the lumbosacral junction (LSJ) was positioned in flexion or extension. Barium-impregnated polymethylmethacrylate was used to fill the intervertebral foramina to aid boundary detection. Measurements of interest were obtained.

RESULTS

Among the dog cadavers, there was large variability in LSIF cross-sectional areas (range, 0.12 to 0.44 cm2; SD, 0.1 cm2) and in foraminal angles required to obtain a double oblique plane in LSJ extension (SD, 8 ° to 9 °). For LSIF area measurements in standard sagittal CT images, interobserver variability was 23% to 44% and intraobserver variability was 4% to 5%. Sagittal oblique images obtained during LSJ extension yielded smaller mean LSIF areas (0.30 cm2), compared with findings in sagittal images (0.37 to 0.52 cm2). The exit and middle zone areas were smaller than the entrance zone area in sagittal images obtained during LSJ extension.

CONCLUSIONS AND CLINICAL RELEVANCE: Repeated measurements of the LSIF area in images obtained during LSJ extension may be unreliable as a result of interobserver variability and the effects of dog positioning and CT slice orientation.

Для цитирования: Higgins Brent M, Cripps Peter J, Baker Martin, Moore Lee, Penrose Fay E, McConnell James F. Effects of body position, imaging plane, and observer on computed tomographic measurements of the lumbosacral intervertebral foraminal area in dogs.. American journal of veterinary research. 2011. DOI: 10.2460/ajvr.72.7.905.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.