MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1503/cjs.014022

Медицинская библиотека · Canadian journal of surgery. Journal canadien de chirurgie · 2024

Total hip arthroplasty with monobloc press-fit acetabular components and large-diameter bearings for atypical acetabula is safe: a consecutive case series of 125 hips with mean follow-up of 9 years.

Synnott Paul-André, Kiss Marc-Olivier, Shahin Maged, Morcos Mina W, Binette Benoit, Vendittoli Pascal-André

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Large-diameter head (LDH) total hip arthroplasty (THA) with a monobloc acetabular component improves hip stability. However, obtaining initial press-fit stability is quite challenging in atypical acetabula. The purpose of this study was to assess primary and secondary fixation of monobloc cups in atypical acetabula.

METHODS

In this consecutive case series, the local arthroplasty database was used to retrospectively identify patients with secondary osteoarthritis who underwent primary hip replacement with press-fit only LDH monobloc acetabular components between 2005 and 2018 and who had a minimum of 2 years of follow-up. Radiographic evaluation was performed at last follow-up, and patient-reported outcome measures (PROMs) were assessed with the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Forgotten Joint Score (FJS), and the Patient's Joint Perception (PJP) question.

RESULTS

One hundred and six LDH THAs and 19 hip resurfacings were included in the study. Preoperative diagnoses included hip dysplasia (36.8%), Legg-Calve-Perthes disease (32.0%), osteoarthritis with acetabular deficiency (17.6%), periacetabular osteotomy (8.0%), arthrodesis (4.0%), and osteopetrosis (1.6%). After a mean follow-up of 9.2 years, no aseptic loosening of the acetabular component was recorded nor observed on radiologic review. There were 13 (10.4%) revisions unrelated to the acetabular component fixation. The mean WOMAC and FJS scores were 9.2 and 80.9, respectively. In response to the PJP question, 49.4% of the patients perceived their hip as natural, 19.1% as an artificial joint with no restriction, 31.5% as an artificial joint with restriction, and none as a non-functional joint.

CONCLUSION

Primary press-fit fixation of monobloc acetabular components with LDH implanted in atypical acetabula led to secondary fixation in all cases with low revision and complication rates and great functional outcomes. With careful surgical technique and experience, systematic use of supplemental screw fixation is not essential in THA with atypical acetabula.

Для цитирования: Synnott Paul-André, Kiss Marc-Olivier, Shahin Maged, Morcos Mina W, Binette Benoit, Vendittoli Pascal-André. Total hip arthroplasty with monobloc press-fit acetabular components and large-diameter bearings for atypical acetabula is safe: a consecutive case series of 125 hips with mean follow-up of 9 years.. Canadian journal of surgery. Journal canadien de chirurgie. 2024. DOI: 10.1503/cjs.014022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.