MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hansur.2024.101975

Медицинская библиотека · Hand surgery & rehabilitation · 2024

A new high-frequency ultrasound classification of De Quervain tenosynovitis.

Yang Xiaoliang, Zhang Xu, Ma Xiuqing, Han Mei, Yu Yadong, Mi Shijun

СтатьяПеревод в очереди

Аннотация

PURPOSE: This study aimed to introduce a new high-frequency ultrasound classification of De Quervain tenosynovitis based on a large group of patients. Detailed characteristics of classification are also reported.

METHODS

From January 2014 to February 2024, patients diagnosed with De Quervain tenosynovitis were retrospectively reviewed. High-frequency ultrasound (7-14 MHz) scanning was performed to identify the anatomy of the extensor pollicis brevis and abductor pollicis longus tendons, presence of intertendinous septa, and pathologic changes. The affected wrist was compared to the contralateral wrist.

RESULTS

453 patients were included: 65 male and 388 female; mean age, 46 ± 27 years (range, 24-65 years). Symptom duration was 14 ± 27 weeks. Disease types were type 0 (n = 5), type 1 (n = 195), type 2a (n = 72), type 2b (n = 18), type 2c (n = 50), type 3 (n = 59), type 4 (n = 45), and type 5 (n = 9). Mean retinacular thickness was 2.1 ± 0.5 mm in affected wrists and 0.4 ± 0.1 mm in contralateral wrists (p < 0.01). The intercompartmental septum was significantly thicker on the affected side (1.2 ± 0.7 mm) than on the asymptomatic side (0.1 ± 0.4 mm) (p < 0.01).

CONCLUSIONS

This novel classification provides detailed ultrasonographic characteristics of De Quervain tenosynovitis, based on a large population of patients. It may help in selecting treatment and predicting outcome. However, relevance and therapeutic significance remain to be demonstrated.

LEVEL OF EVIDENCE: Therapeutic study, Level IV.

Для цитирования: Yang Xiaoliang, Zhang Xu, Ma Xiuqing, Han Mei, Yu Yadong, Mi Shijun. A new high-frequency ultrasound classification of De Quervain tenosynovitis.. Hand surgery & rehabilitation. 2024. DOI: 10.1016/j.hansur.2024.101975.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.