Background

Hallux rigidus is a painful and degenerative pathology of the first metatarsophalangeal (MTP1) joint. In severe cases it is usually appropriate to consider arthrodesis or arthroplasty of the joint. Arthrodesis represents the gold standard, but arthroplasty allows patients to recover mobility. Although arthroplasty has slightly inferior functional results to arthrodesis, it has shown very good results in terms of joint mobility, patient satisfaction and pain reduction. The goal of the present study was to evaluate short-term outcomes of patients that received a third-generation double-stemmed MTP1 implant manufactured from high-performance silicon.

Methods

In this retrospective study the authors analyzed data of 37 patients who underwent MPT1 joint arthroplasty with SilktoeTM double-stemmed implant using the R 4.2.2 software (R Foundation for Statistical Computing, Vienna, Austria). The indications were hallux rigidus of grade III and grade IV (81.1%), hallux rigidus plus valgus (10.8%), painful or unstable joint following previous surgery (5.4%) and hallux rigidus due to gout (2.7%). Data were collected during routine visits at 1 and 6 months and 1 and 2 years.

Results

There were no intraoperative and postoperative complications. There were no revisions or reoperations at a follow-up of two years. The American Orthopaedic Foot and Ankle Society-Hallux Metatarsophalangeal-Interphalangeal Scale (AOFAS-HMI) score was 94.6 ± 7.6 (median, 100; range, 70-100) and the Visual Analogue Scale (VAS) score was 0.4 ± 0.80 (median, 0; range, 0-3.5) at the final follow-up.

Conclusions

The data from this study presented excellent short-term results for patients who received an arthroplasty of the MTP1 joint using a third-generation double-stemmed spacer made of high-performance silicone. For all patients who received the SilktoeTM implant, AOFAS-HMI scores of 94.6 and VAS scores of 0.4 were obtained at a two-year follow-up. These values were in line with results reported in the literature for similar devices.

Для цитирования: Fieschi Stefano, Redaelli Costanza, Fazzini Anita. Short-Term Outcomes of First Metatarsophalangeal Arthroplasty Using the Silktoe Double-Stemmed Silicone Implant.. Diagnostics (Basel, Switzerland). 2025. DOI: 10.3390/diagnostics15111349.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.