MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jum.16697

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025

Intraobserver Reliability of Two-Dimensional Ultrasound Measurements of the Linea Alba in Parous Women During Different Abdominopelvic Exercises.

Espinoza-Bravo Claudia, Rejano-Campo Montserrat, Domínguez-Navarro Fernando, de Gasquet Bernadette, Fuentes-Aparicio Laura

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the intraobserver reliability of Diastasis Recti Abdominis (DRA) measurement by ultrasonography during four specific abdominopelvic exercises, evaluating interrecti distance, Linea Alba (LA) thickness, and distortion index in parous women.

METHODS

Fifty-four parous women were assessed using ultrasound imaging for the LA. Four exercises were evaluated: crunch, abdominal drawing-in maneuver, pelvic floor muscle contraction, and one exercise based on the de Gasquet Method. Each exercise was performed three times. The ultrasound probe was placed 3 cm above and 2 cm below the umbilicus. Interrecti distance (IRD), distortion index, and LA thickness were measured and analyzed using ImageJ software by independent researchers. Intraobserver reliability was evaluated using the intraclass correlation coefficient (ICC) with a 95% confidence interval.

RESULTS

ICC values for the IRD ranged from 0.84 to 0.99 for the four exercises. The distortion index showed moderate to high reliability (ICC: 0.77-0.98), while LA thickness also demonstrated moderate to high reliability (ICC: 0.75-0.98).

CONCLUSION

The results demonstrate the reliability of ultrasound in measuring key parameters, including LA thickness, distortion, and IRD in women with DRA during various exercises. As a non-invasive tool, it supports evidence-based interventions in postpartum recovery and clinical practice.

Для цитирования: Espinoza-Bravo Claudia, Rejano-Campo Montserrat, Domínguez-Navarro Fernando, de Gasquet Bernadette, Fuentes-Aparicio Laura. Intraobserver Reliability of Two-Dimensional Ultrasound Measurements of the Linea Alba in Parous Women During Different Abdominopelvic Exercises.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2025. DOI: 10.1002/jum.16697.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.