MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2026.01.012

Медицинская библиотека · The Journal of arthroplasty · 2026

How Effective Are Constrained Liners at Preventing Dislocation After Revision Total Hip Arthroplasty?

Shah Sharrieff N, Leal Justin, Stein Matthew K, Deckey David G, Schwartz Andrew M, Bolognesi Michael P, Ryan Sean P

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Recurrent instability continues to challenge arthroplasty surgeons, and constrained liners may be utilized for cases of recurrent or multidirectional instability following revision total hip arthroplasty (rTHA). The purpose of this study was to evaluate dislocation rates and survivorship after rTHA using constrained liner (CL) prostheses.

METHODS

Patients who underwent rTHA using a CL prosthesis were retrospectively reviewed from January 1, 2013, to December 31, 2024. Patients who had antibiotic spacers or megaprostheses, or those who had less than one year of follow-up, were excluded. Survivorship analyses were performed to determine dislocation and reoperation-free survivorship through follow-up. A total of 98 rTHAs with CL were included, with a mean follow-up time of 3.9 years (range, one to 10.8).

RESULTS

The CL dislocation rate at final follow-up was 16.3% (16 of 98), and the 9-year dislocation-free survivorship was 71% (95% confidence interval [57 to 89]). There was neither statistically significant difference in 9-year dislocation-free survivorship among CL systems (P = 0.73), CLs inserted into cups that were retained versus revised (P = 0.95), nor CLs that were snapped in versus cemented (P = 0.38). The overall reoperation rate at final follow-up was 49.0% (48 of 98), and the 9-year all-cause reoperation-free survivorship was 33% (95% confidence interval [17 to 62%]). Of those 48 requiring reoperation, 27 (56.2%) were for infection and 14 (29.2%) were for recurrent hip instability. There was neither statistically significant difference in 9-year all-cause reoperation-free survivorship among CLs inserted into cups that were retained versus revised (P = 0.67) nor CLs that were snapped in versus cemented (P = 0.34).

CONCLUSIONS

In a cohort where a majority of patients had multiple prior rTHAs secondary to hip instability, CLs were a salvage option for preventing repeat dislocation; however, dislocation and reoperation rates remain high.

LEVEL OF EVIDENCE: Level III Evidence, Retrospective Cohort Study.

Для цитирования: Shah Sharrieff N, Leal Justin, Stein Matthew K, Deckey David G, Schwartz Andrew M, Bolognesi Michael P, Ryan Sean P. How Effective Are Constrained Liners at Preventing Dislocation After Revision Total Hip Arthroplasty?. The Journal of arthroplasty. 2026. DOI: 10.1016/j.arth.2026.01.012.